User`s guide
Configuration Commands in Detail
help Display basic help information
This command is used to display brief help information. For detailed help
information the manual should always be consulted!
exit Exit configurator
This command exits the radio modem configuration mode and returns it to the
data transfer mode. A soft reset of the modem occurs when returning to the
data transfer mode, after which the updated settings will take immediate effect.
ser Display the unit serial number
This command displays the radio modem type, serial number and firmware
version information.
list Display the current Radio Modem configuration
This command displays a list of the current radio modem user configured
settings.
default Load factory settings
This command loads the configuration stored and programmed at the factory.
This operation replaces all of the configuration options with factory default
values.
The list below shows the factory default values which are written to non-volatile
memory using the default command:
baud 9600
airspd 9600
2400 for RMX232-151/173
unit 0
site 0
hop 0
flow none
(no flow control)
dlytx 4 (x10ms) 25 for RMX232-151/173
retry 5
ctime 10 (secs)
(connection timeout)
dtr off
(DTR power down control disabled)
batmon off (battery monitoring disabled)
signon on (signon message enabled)
remote off (remote configuration disabled)
cmdchar 43(+) 100(x10ms)
rptmode off
(repeater mode disabled)
ptpmode on (point-to-point mode enabled)
User’s Guide Configuration Commands 3-2