Instructions

BLHeliSuite MultipleESC mode 14.3.0.2 and later ©4712
Introduction
The BLheliSuite MultipleESC mode does work with an appropriate interface (4way-interface) or an
appropriate option for a Flight Controller interface (like “1wire pass-through” for Cleanflight or
Betaflight).
The maximum number of available ESC channels is 8 (Some interface support less ESC e.g. TAQX box) .
In “1wire pass-through” mode the number of accessible ESC will be detected automatically and the
buttons will show up accordingly (e.g. 4 buttons for a “Quad X” or 6 for a “Hex X “configuration…).
Getting started
If the interface is not yet connected and one clicks “Read Setup“ or “Flash BLHeli” or “Flash Other”, at
first an automatic “Check” will be executed. The “Check” tries to read all available channels for
connected ESC and shows a result dialog.
A manual “Check” can be initiated at any time by clicking the button
The “Check” generally tries to read all available channels for connected ESC, and shows the following
scenario after it found 4 ESC at channel #1,#2,#3 and #4.
2