Battery - Safety Data Sheet
Wet Flooded Lead-Acid Battery
Safety Data Sheet
according to Regulation (EU) 2015/830
EN (English)
4/13
Methods for cleaning up
:
Small spills:collect all released material in a plastic lined metal container. . Take up liquid spill
into absorbent material or Neutralize with sodium bicarbonate. Large spills:contain liquid using
absorbent materila, by digging trenches. Take up liquid spill into inert absorbent material, e.g.:
sand/earth. Dispose in a safe manner in accordance with local/national regulations.
6.4. Reference to other sections
No additional information available
SECTION 7: Handling and storage
7.1. Precautions for safe handling
Additional hazards when processed
:
Protect from physical damage.
Precautions for safe handling
:
Avoid all eye and skin contact and do not breathe vapour and mist. Since emptied containers
retain product residue, follow label warnings even after container is emptied.
Hygiene measures
:
Do not eat, drink or smoke when using this product.
7.2. Conditions for safe storage, including any incompatibilities
Technical measures
:
Provide local exhaust or general room ventilation.
Storage conditions
:
Store in a dry, cool and well-ventilated place. Keep away from heat and direct sunlight.
7.3. Specific end use(s)
No additional information available
SECTION 8: Exposure controls/personal protection
8.1. Control parameters
Lead (7439-92-1)
EU
European BEI
(Medium: blood - Time: no restriction - Parameter:
Lead (binding biological limit value)
0,075 mg/m³ (Medium: air - Time: 40 hours per week -
Parameter: Lead (TWA medical surveillance threshold
in air measured as a time weighted average over 40
hours per week)
(Medium: blood - Time: no restriction - Parameter:
Lead (medical surveillance threshold measured in
individual workers)
Austria
MAK (mg/m³)
0,1 mg/m³ (inhalable fraction)
Austria
MAK Short time value (mg/m³)
0,4 mg/m³ (inhalable fraction)
Bulgaria
OEL TWA (mg/m³)
0,05 mg/m³
Bulgaria
Bulgaria - BEI
300 μg/l (Medium: blood - Time: not fixed - Parameter:
Lead (for women under 45 years old)
400 μg/l (Medium: blood - Time: not fixed - Parameter:
Lead)
Croatia
GVI (granična vrijednost izloženosti) (mg/m³)
0,15 mg/m³
Croatia
Croatia - BEI
(Medium: blood - Time: not critical - Parameter: Lead
(Medical surveillance should be carried out when the
limit value of Lead in blood of workers >40 µg/100mL
blood)
(Medium: urine - Time: single sample or urine
collected over 24 hours - Parameter: Lead (For all
results that are expressed on Creatinine, Creatinine
concentration <0.5 g/L and >3.0 g/L should not be
considered)
(Medium: blood - Time: not critical - Parameter: .delta.-
Aminolevulinic acid dehydratase)
(Medium: blood - Time: after exposure during 2-3
months (light protected sample) - Parameter:
Protoporphyrin in erythrocytes (Interference of Iron
deficiency (anemia sideropenic))
Cyprus
OEL TWA (mg/m³)
0,15 mg/m³
Czech Republic
Expoziční limity (PEL) (mg/m³)
0,05 mg/m³