Product Manual
Page 9
Parameter
Minimum
Maximum
Nominal
CE/UL (CSA )
*optional
Table 3-1: Operating Specification
Inlet Pressure
Inlet Temperature
60 psig (4.1barg) 230 psig (16.0 barg)
100 psig (6.9 barg)
40°F (4.4°C) 120°F (48.9°C) 95°F (35°C)
Table 3-2: Electrical Specification
Dryer Model Voltage Supply Supply Need Electrical Approval
50-60 Hz 115-240V
1 phase
Control Air Pressure 60 psig (4.1barg) 145 psig (10 barg)
87 psig (6 barg)
Ambient Air Temperature 34°F (1,6°C) 122°F (50°C)
100°F (38°C)
SPECIFICATIONS
Performance data based on 100°F (38°C) ambient temperature, 100°F (38°C)inlet temperature and 100
psig (6,9 barg) inlet pressure.
NOTE
EMD US-25
EMD US-45
EMD US-110
EMD US-120
EMD US-190
EMD US-260
20
40
100
120
180
240
35
70
170
200
300
400
1/2”
1 1/2”
1 1/2”
1 1/2”
1 1/2”
1 1/2”
350
495
622
622
734
889
13,8
19,5
24,5
24,5
28,9
35
370
410
430
430
410
410
14,5
16,1
22
25
16,1
16,1
1108
1250
1450
1750
1499
1497
43,6
49,2
58
68,8
59
59
42
71
133
152
186
235
92
156
292
334
409
517
115-240V/ 50-60Hz
115-240V/ 50-60Hz
115-240V/ 50-60Hz
115-240V/ 50-60Hz
115-240V/ 50-60Hz
115-240V/ 50-60Hz
MODEL
TYPE
INLET FLOW
RATE
INLET-OUTLET
CONNECTION
LENGTH WİDTH HEIGHT WEIGHT VOLTAGE
mm inc kg lbs
CFM (m³/h)
mm inc mm inc
EMD US-25
EMD US-45
EMD US-110
EMD US-120
EMD US-190
EMD US-260
20
40
100
120
180
240
35
70
170
200
300
400
1/2”
1 1/2”
1 1/2”
1 1/2”
1 1/2”
1 1/2”
5
5
5
5
5
5
2,5
2,5
2,5
2,5
2,5
2,5
2
2
2
2
2
2
30
30
30
30
30
30
Dry Air
Dry Air
Dry Air
Dry Air
Dry Air
Dry Air
15%
15%
15%
15%
15%
15%
20%
20%
20%
20%
20%
20%
10
18
43
53
67
89
22
39
94
116
147
195
MODEL
TYPE
INLET FLOW
RATE
INLET-OUTLET
CONNECTION
CFM (m³/h)
NEMA cycle
in minutes
Drying time
in minutes
Regen. time
in minutes
Purge
Source
Purge Rate
(at -40°C)
(-40°F)
Purge Rate
(at -70°C)
(-100°F)
Activated
Alumina
(kg) ibs
Repress. time
in seconds
NPT
NPT
3.2 TECHNICAL SPECIFICATION