Installation Guide
TECHNICAL FILE
R03.002_18/05/2011
2,3
9,4
17,6
4,6
9,7
21,9
0
5
10
15
20
25
No R floor test
R9 floor test
R10 floor test
Slip resistance Novopeldaño® Maxi
Original floor
Floor combined with Maxi
Novopeldaño® Maxi
Page 2 of 3
Slip resistance Very good.
UNE-ENV 12633:2003
Slip resistance Very good. See graph below.
DIN 51130
Slip resistance DIN51130
We have tested our Novopeldaño® Maxi under the DIN 51130 standard, to certify its good properties
of slip resistance. This reference had been already tested before under the Spanish standard UNE-
ENV 12633:2003, which is the one required by the CTE (Spanish Technical Building Code).
The tests were carried out in several panels (1000x500 mm.) which consisted of ceramics with
different classications of slipperiness, combined with our Novopeldaño® MaxiKenya proles as it
is shown in the picture.
These tests were carried out by qualied operators of the ITC (Technological Institute of Ceramics).
The results are also available for our reference Novopeldaño® Maxi. Please, check its technical le.
The graph below represents the global results after the tests. The dark red line represents the results for the original ooring,
and the clear one the results in combination with Novopeldaño® Maxi.
The rst ooring tested had a low initial value (2.3), that improved up to 6.5 with Novopeldaño® Maxi, which means that the
initial sliding ooring became a non-slip R9 ooring. The second ooring, certied as R9 (9.4 value) improved its slip resistance
value up to 12.7, changing its classication from R9 class to R10 class. Finally, the last ooring classied as R10 with a value of
17.6, in combination with the prole got a result of 23.7 and R11 class.
Class R9