Instructions

AT commands
Function AT command
AT+START=OK Start charging process
AT+START=ERR,<CODE>
Code 1: Vehicle not connected
Code 2: System fault
Code 3: Charging in process
Code 4: Charging not available
Schedule charging
AT+START=1,<TIME>
<TIME> = 2021/01/01 12:30
AT+START=OK Charging process scheduled for given time
End charging AT+STOP AT+STOP=OK End charging process
AT+SETRATE=OK,<VALUE>
AT+SETRATE=ERR,<VALUE>
Monitor charging station AT+REALDATA
AT+REALDATA=<STA>,<METER_KWH>,<
CHARGE_KWH>,<VOLTAGE>,<CURRENT
>,<TIME>,<TEMP>,<FCODE>,<FFLG>,<EC
ODE>,<RATE>
STA 0: Standby
STA 1: Connected
STA 2: Start charging process
STA 3: Charging in process
STA 4: Error while starting charging process
STA 5: Charging process finished
STA 6: Error
METER_KWH: Total meter reading (KWh)
CHARGE_KWH: Current meter reading (KWh)
VOLTAGE: Charging voltage (V)
CURRENT: Charging current (A)
TIME: Charging time (Min)
TEMP: System temperature (°C)
FCODE: See table: Error codes
FFLG: See table: Error codes
ECODE: See table: E-Codes
RATE: Set output current (A)
jk
Charge mode: on RFID autorizati
AT+SETMODE=0
Charge mode: Immediately AT+SETMODE=1
Beep acoustic signal
AT+BEEP=<N>
<N> = Number of signals
AT+BEEP=OK Acoustic signal will be played
Get software version AT+VER AT+VER=<VERSION>
Get serial number AT+SN AT+SN=<SERIALNUMBER>
AT+SETMODE=OK Setting successful
Response
Start charging AT+START=0
Set max. output (Amp)
AT+SETRATE=<VALUE>
<VALUE> = 8 to 32
Setting successful
14