Instructions

9
GB
Type 2 plug 3-phase type 2 socket
Thank you for choosing the EM2GO electric vehicle
charging station.
With this smart wallbox, you have chosen a high-precision charger equipped with many
safety-related protection devices, as well as interfaces, which guarantees all-round carefree
charging of your vehicle and limitless communication.
Important Note:
Please read these important safety instructions for charging your vehicle.
Please keep this user manual. The charger has many safety functions. Read all safety
information and warnings in this manual to become aware of possible dangers.
Warning
When using electrical products, these basic precautions must always be observed.
• Do not install or use the charger near explosive, corrosive or ammable materials,
chemicals or vapors.
• The charger may only be installed on non-ammable surfaces such as concrete, and at least
120cm above the ground.
• The charger must be securely grounded.
• Turn o󰀨 the power to the charger before installing or servicing the charger.
• The charger is designed only for vehicles that are compatible with the IEC 62196 standard
for charging modes.
• Do not use the charger if it is defective or has visible damage.
• Do not attempt to open, disassemble, repair, tamper with, or modify the unit. If you have any
questions or need repairs, contact our customer service department.
• Do not use the charger when you are in the vehicle.
• Do not use the charger when exposed to heavy rain, snow or inclement weather.
Always exercise caution when transporting the charger.
• Do not touch the charging connector with sharp metallic objects.
• Do not pull the charging cable with force or over sharp objects.
Warning
The device must be installed, adjusted and serviced by qualied electricians or
people who are familiar with the construction and operation of this type of EV-Charger
Failure to follow this precaution could result in death or serious injury.
• Incorrect installation and testing of the charger can possibly lead to damage. No liability will
be accepted for any resulting damage.
• Ensure that the charging cable is correctly positioned during the charging process and
cannot be stepped on, damaged or stressed.
• Check the wire diameter according to local electrical requirements.
• Turn o󰀨 the appropriate power supply before beginning installation.
• The charger must be installed and commissioned by qualied personnel.
• Before installation, the supply cable and house connection values must be checked.
Abbreviations:
A | Ampere, unit of current
V | Volt, unit of voltage
EV | Electric vehicle
EVSE | Electric Vehicle Supply Equipment EV according to IEC61851-1
RFID | Radio Frequency Identication Card
OCPP | Open Charge Point Protocol, universal communication interface
with a central system (backend)
IP | Protection class
RCCB | Type B fault circuit breaker
MCB | Miniature Circuit Breaker
Technical data:
• Operating voltage: 400V AC ±10%, 50-60 Hz, 3-phase
• Operating current: 16A for 11 KW and 32 A for 22 KW
• Max. Output power Typically 11 or 22 kW
• Housing: IP54, splash-proof
• Input terminals: L1, L2, L3, N, PE
• Connection: Type 2 plug (CT) | Type socket (ST)
• 3 charging modes
• Communication interfaces: Ethernet 10MBit/s (10BASE-T) (RJ45),
WLAN 802.11b/g/n (2.4GHz), RS-485, PLC, OCPP 1.6-J
• Safety features: Emergency stop button, overvoltage protection, undervoltage protection,
overtemperature and overcurrent protection, lightning protection, residual current
(RCD type B + circuit breaker).
• Display: Color LCD 4.3 inches, LED diodes
• Structure: CE standards IEC 61851-1: 2017 IEC 62196-2:2016, IEC 60364-7-722:2018.
• Construction: Front panel glass, back panel metal
• Connection length: 7.5 meters (CT)
• Operating temperature: -30 to + 55 °C
• Dimensions: 410 x 260 x 140 mm
• Weight: 12 Kg
Representation of Type2 plug / socket
according to IEC 62196-2