Technical data
Technical specifications
4
Safety instructions
Electrical connections have to be made by a qualified electrician.
Install the Hotrun as close as possible to the tap(s) in a frost-free space.
Make sure the power supply is shut off at all times installing or servicing a Hotrun.
Fit a service valve in the water supply to the Hotrun.
Do not operate the Hotrun in a “dry state”, the electrical power should not be switched on
before the Hotrun has been completely filled with water.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard.
Read these instructions for safety and installation carefully before starting to install!
Model 35 46 60 72 90
Rating (kW) 3.5 4.6 6.0 7.2 9.0
Current (A) 16 20 25 2x16/32 2x20/40
Minimum pressure for all models: 1 bar / 100 kPa
Maximum pressure for all models: 10 bar /1MPa
Guaranteed Flow Rates at 37°C outlet temperature
l/min when 1.9 2.5 3.6 4.0 5.1
inlet temp. = 12°C
l/min when 4.3 5.4 7.5 8.4 10.5
inlet temp. = 25°C
Electrical Approvals to European and Australian standards IEC & AS/NZS 60335:2:35
and Australian Plumbing Standard AS/NZS 3498 & 3500, WaterMark approval no. 40034
Selection/applications of Hotrun models (varies per State due to inlet temperature)
Hand basin ✔T ✔T
Hairdressers shampoo basins ✔T ✔T ✔T ✔T
Showers and basins ✔T ✔T
Commercial applications ✔ ✔ ✔ ✔