- AUX OUTPUT
The dome provides 2 auxiliary outputs, each alarm output corresponding to one auxiliary output. Available settings include:
1: An alarm action will close AUX1.
2: An alarm action will close AUX2.
NONE: No auxiliary will be activated.
- ALARM INPUT
It is used for defining alarm input signal type. Available settings include:
OPEN: Normally open.
CLOSE: Normally closed.
OFF: Disable the alarm input.
3.3.10 AUXS
An auxiliary output is a configurable signal from the dome back box that can trigger another device to operate. Refer to Figure
3.3.28 for the AUXS settings menu.
- AUX OUTPUT
It is used for defining alarm output type. Available settings include OPEN (default) and CLOSE, which correspond to normally
open and normally closed respectively.
- DWELL TIME
The duration of the AUX output signal, with 0~60 seconds configurable.
NB: This camera is not equipped with alarm function
CLEAR SETTINGS
CLEAR ALL PRESETS
CLEAR ALL PATROLS
CLEAR ALL PATTERNS
CLEAR ALL BLANKS
CLEAR ALL ZONES
CLEAR ALL TIME TASKS
<DIAGNOSTICS>
BACK EXIT
Figure 3.3.28 Figure 3.3.29
AUX
AUX1 CLOSE
DWELL TIME 2
AUX1 OPEN
DWELL TIME 0
BACK EXIT
3.3.11 CLEAR SETTINGS
Refer to Figure 3.3.29 for the CLEAR SETTINGS menu.
Use this menu to clear all user-defined settings, including presets, patrols, patterns, window blanks, zones and time tasks.
As shown in Figure 3.3.30 and Figure 3.3.31, the dome provides self-diagnostics function for the occurrence frequency of the
following events: high temperature (>65 ), low temperature (<25 ), video loss, low voltage, abnormal reboot, pan sync loss, tilt
sync loss and camera sync loss.
DIAGNOSTICS
PAN LOST 0
TILT LOST 0
CAMERA LOST 0
BACK EXIT
Figure 3.3.30 Figure 3.3.31
DIAGNOSTICS
HIGH TEMP 0
HIGHEST TEMP 35°C
LOW TEMP 0
LOWEST TEMP 14°C
VIDEO LOSS 0
LOW VOLATE 0
POWER UP 0
BACK EXIT