Installation manual

Figure 4
For such case, the best way is adding a RS485 distributor. This product can effectively change the star-shape connection to
which satisfies the requirement of RS485 industry standard, in order to avoid those problems and improve the communication
reliability. Show as figure 5.
1. FAQ of RS485 Bus
Fault Phenomenon Probable Cause Solutions
The speed dome do
the self chack but an
not be controlled
1. The address or Baud Rate is not matched bet-
ween Host and the speed Dome
1. Adjust the address or Baud Rate of Host or
Speed Dome to make a match
2. RS485+, - are connected incorrectly 2. Change the RS 485+ and RS485- wires
3. Wiring drops 3. Fastening the wire
4. RS485 wire broke: 4. Change RS485 wire
The speed dome can
be controlled but not
smoothly
1. Loose contact of RS485 1. Fastening RS485 wire
2. One RS485 wire broke 2. Change RS485 wire
3. Host and speed dome are too far away 3. Add terminal matched resistance
4. Too many speed domes are connected 4. Add RS485 distributor