Specifications
65
Table 25 — Staging Sequence Without Hot Gas Bypass — 48/50AK,AY020-027 and Multi-Stage 48/50AJ,AW
Table 26 — Staging Sequence With Hot Gas Bypass — 48/50AK,AY020-027 and Multi-Stage 48/50AJ,AW
*With MLV Valve ON.
Table 27 — Staging Sequence Without Hot Gas Bypass — 48/50AK,AY030-060 and Adaptive 48/50AJ,AW
Table 28 — Staging Sequence With Hot Gas Bypass — 48/50AK,AY030-060
*With MLV Valve ON.
STAGE
SEQUENCE 1 SEQUENCE 2
0123 4 0123 4
COMP Compressor Status Compressor Status
A1 OFF ON ON OFF ON OFF OFF ON ON ON
A2 OFF OFF ON ON ON OFF ON ON OFF ON
B1 OFF OFF OFF ON ON OFF OFF OFF ON ON
Unit Capacity 48/50A Unit Capacity 48/50A
20 0% 33% 67% 67% 100% 0% 33% 67% 67% 100%
25 0% 30% 65% 70% 100% 0% 35% 65% 65% 100%
27 0% 33% 67% 67% 100% 0% 33% 67% 67% 100%
STAGE
SEQUENCE 1 SEQUENCE 2
01234 5 01234 5
COMP Compressor Status Compressor Status
A1 OFF ON* ON ON OFF ON OFF OFF OFF ON ON ON
A2 OFF OFF OFF ON ON ON OFF ON* ON ON OFF ON
B1 OFF OFF OFF OFF ON ON OFF OFF OFF OFF ON ON
Unit Capacity 48/50A Unit Capacity 48/50A
20 0% 18% 33% 67% 67% 100% 0% 18% 33% 67% 67% 100%
25 0% 17% 30% 65% 70% 100% 0% 22% 35% 65% 65% 100%
27 0% 21% 33% 67% 67% 100% 0% 21% 33% 67% 67% 100%
STAGE
SEQUENCE 1 SEQUENCE 2
01234 5 01234 5
COMP Compressor Status Compressor Status
A1 OFF ON ON OFF ON ON OFF OFF ON ON ON ON
A2 OFF OFF ON ON ON ON OFF ON ON OFF ON ON
B1 OFF OFF OFF ON ON ON OFF OFF OFF OFF OFF ON
B2 OFF OFF OFF OFF OFF ON OFF ON OFF ON ON ON
Unit Capacity 48/50A Unit Capacity 48/50A
30 0% 23% 45% 50% 73% 100% 0% 23% 45% 50% 73% 100%
35 0% 22% 48% 52% 74% 100% 0% 26% 48% 48% 74% 100%
40 0% 21% 43% 50% 71% 100% 0% 21% 42% 50% 72% 100%
50 0% 23% 45% 45% 68% 100% 0% 23% 45% 54% 77% 100%
60 0% 24% 50% 50% 74% 100% 0% 26% 50% 50% 76% 100%
STAGE
SEQUENCE 1 SEQUENCE 2
012345 6 012345 6
COMP Compressor Status Compressor Status
A1 OFF ON* ON ON OFF ON ON OFF OFF OFF ON ON ON ON
A2 OFF OFF OFF ON ON ON ON OFF ON* ON ON OFF ON ON
B1 OFF OFF OFF OFF ON ON ON OFF OFF OFF OFF OFF OFF ON
B2 OFF OFF OFF OFF OFF OFF ON OFF OFF ON OFF ON ON ON
Unit Capacity 48/50A Unit Capacity 48/50A
30 0% 12% 23% 45% 50% 73% 100% 0% 12% 23% 45% 50% 73% 100%
35 0% 12% 22% 48% 52% 74% 100% 0% 16% 26% 48% 48% 74% 100%
40 0% 13% 21% 43% 50% 71% 100% 0% 13% 21% 42% 50% 72% 100%
50 0% 16% 23% 45% 45% 68% 100% 0% 16% 23% 45% 54% 77% 100%
60 0% 19% 24% 50% 50% 74% 100% 0% 21% 26% 50% 50% 76% 100%