Specifications

Appendix D – Manufacturing Test and Handling Guidelines
238 PL 3120/PL 3150/PL 3170 Power Line Smart Transceiver Data Boo
k
A/D, D/A- based Test System
This section describes a practical test system that can perform both transmit and receive performance verification.
Hardware Description
The test system should have the following components.
Data acquisition hardware
Test interface board
Data Acquisition Hardware
A 12-bit A/D channel with a throughput of at least 1 Ms/s that is configured for single ended reference and
±10V range
A 12-bit D/A channel with a throughput of at least 1Ms/s that is configured for ±10V range
Data acquisition channels that have an external trigger capability
National Instruments multi-function cards, such as PXI-6070E or PCI-MIO-16E-1, are examples of data acquisition
hardware that meet the requirements for the test system.
Test Interface Board
A custom interface board needs to be designed that provides 70dB attenuation, a ~5 ohm load, a coupling circuit, and a
peak detector circuit that triggers on the UUT transmitted packets. Figure D.1 is a diagram of circuitry that provides the
required interface functions.
Figure D.1 Test Interface Board