Specifications

PL 3120/PL 3150/PL 3170 Power Line Smart Transceiver Data Book 227
30
Diode D102 – Ground clamp diode
Current Rating 1A
Reverse breakdown 50V
Forward voltage 1.0V@1A/25C
Surge current 30A for 8.3ms
Reverse recovery 25ns
Reverse current 100uA@100C
Typical capacitance 40pF@4V
31 *
Fuse F101 – Line fuse
6A or 6.3A rating (or higher if in accordance with varistor vendor recommendations)
Proper voltage rating
Time-lag (slow-blow type)
32
Inductor L101 – Shunt coupling inductor (for a non-transformer isolated coupling circuit)
1.0mH value
10% (or better) tolerance
DC current rating 30mA
DC resistance 14Ω
33
Inductor L102 – Series coupling inductor (if applicable)
Proper value
10% (or better) tolerance
Proper DC current rating
Proper DC resistance
If toroidal or shielded inductor is used a current rating 2 to 3 times higher than listed in the component
table for this inductor is used.
34 *
Inductor L103 – RXCOMP inductor
Proper value
10% (or better) tolerance
DC current rating 30mA
DC resistance 55Ω
1kHz Test Frequency 400kHz
35
Resistor R101 – Safety discharge resistor
Proper value
Proper voltage rating
Proper power rating for hi-pot test (if applicable)
36
PROTECT circuit
If varistor used:
Proper AC or DC voltage rating
Proper surge current rating for 8x20μs for 2 times
No varistor to earth unless hi-pot testing is performed prior to insertion of varistor and ground leakage
current is not an issue.
If gas-discharge tube used place on line side of fuse
37
Transformer T101 (for a transformer isolated coupling circuit)
Transformer with correct specifications is selected (see Appendix C)
38
No filters or power supply transformers are in the coupling circuit path. If a ferrite bead is in the
coupling circuit path it is either common mode connected (see Chapter 6) or has been verified to be
<0.5
Ω @100kHz.
39
L101 and L103 are spaced >1cm apart (for a non-transformer isolated coupling circuit)
40
Circuit board traces between the output of the transmit amplifier and the AC mains are 1.3mm wide
and 15cm long.