Specifications
Chapter 4 – Coupling Circuits
150 PL 3120/PL 3150/PL 3170 Power Line Smart Transceiver Data Boo
k
Table 4.13 Surge Levels of the Example Coupling Circuits
Example Coupling Type Location Type
Ring Wave
(0.5µs-100kHz)
Combination Wave
(1.2/50µs-8/20µs)
Level Tested
with
30 Surge Events
Level Tested
with
4 Surge Events
Level Tested
with
30 Surge Events
Branch circuit 6kV/200A 6kV/500A 2kV/1000A
Power entry 6kV/500A 6kV/3000A 2kV/1000A
1
1-phase, L-N, non-isolated
Outdoor 7.8kV/650A 7.4kV/3700A 4kV/2000A
Branch circuit 6kV/200A 6kV/500A 2kV/1000A
Power entry 6kV/500A 6kV/3000A 2kV/1000A
2
1-phase, L-N, isolated
Outdoor 7.8kV/650A 7.4kV/3700A 4kV/2000A
Branch circuit 4kV/130A 4kV/333A 2kV/1000A
Power entry 6kV/500A 6kV/3000A 2kV/1000A
3
1-phase, L-E, non-isolated
Outdoor 7.8kV/650A 7.4kV/3700A 4kV/2000A
Branch circuit 4kV/130A 4kV/333A 2kV/1000A
Power entry 6kV/500A 6kV/3000A 2kV/1000A
4
1-phase, L-E, isolated
Outdoor 7.8kV/650A 7.4kV/3700A 4kV/2000A
Indoor 6kV/500A 6kV/3000A 2kV/1000A
5
3-phase, non-isolated
Outdoor 7.8kV/650A 7.4kV/3700A 4kV/2000A
Indoor 6kV/500A 6kV/3000A 2kV/1000A
6 3-phase, isolated
Outdoor 7.8kV/650A 7.4kV/3700A 4kV/2000A
8
Power Supply Plus Coupler Branch circuit 4kV/130A 4kV/333A 2kV/1000A