Specifications

PL 3120/PL 3150/PL 3170 Power Line Smart Transceiver Data Book 117
Table 4.6 100-277 VAC, 3-Phase, Non-Isolated Coupling Circuit Component Values
Value Required Specifications Example Vendors / Part numbers
Comp
A-band C-band
A-band C-band
C101A-C 0.15µF 0.10µF
±10%, 250VAC, X2 type (1)
IllinoisCap/154MKP275KB
AID Electronics/
MEX154K275AC
IllinoisCap/104MKP275K
AID Electronics/
MEX104K275AC
C102 1.0µF 1.0µF
±10%, 250VDC, metallized film
Panasonic/ECQ-E2105KB
Surge Components/
SRMA250V105K
Panasonic/ECQ-E2105KB
Surge Components/
SRMA250V105K
C103
220µF 220µF
±20%, 16VDC, aluminum electrolytic,
0.16Ω ESR @100kHz/20C,
550mA
RMS
ripple current @105C
Nichicon/UHE1E221MPD
Fenghua/
8221LDM0812LY
Nichicon/UHE1E221MPD
Fenghua/
8221LDM0812LY
D101,
D102
1A 1A
Reverse breakdown 50VDC, forward
voltage 1.0V @1A/25C, surge current
30A for 8.3ms, reverse recovery 25ns,
reverse current 100µA @100C, typical
capacitance 40pF @4V
Fairchild/ES1B
Vishay/ES1D-E3
OnSemi/MUR120G
Fairchild/ES1B
Vishay/ES1D-E3
OnSemi/MUR120G
6A or
6.3A
6A or
6.3A
For indoor use, 250VAC, time-lag (1),
(2)
Wickmann/3741630041
Hollyfuse/5RT-063H
Wickmann/3741630041
Hollyfuse/5RT-063H
F101A-C
10A 10A For outdoor use, 250VAC, time-lag (1) Wickmann/3742100041 Wickmann/3742100041
L101 1.0mH 1.0mH
±10%, Imax30mA, R
DC
14Ω
Fastron/SMCC/N-102K
Shinhom/LGA0410-102K
TaiyoYuden/
LAL04TB102K
Fastron/SMCC/N-102K
Shinhom/LGA0410-102K
TaiyoYuden/
LAL04TB102K
L102A-C 27µH 18µH
±10%, Imax 1.5A, R
DC
0.15Ω
Taiyo Yuden/
LHL08TB270K
Shinhom/LCHB0810270K
CTC Coils/
CH6080270K-542318-B
Taiyo Yuden/
LHL08TB180K
Shinhom/LCHB0810180K
CTC Coils/
CH6080180K-542316-B
L103 1.5mH 820µH
±10%, Imax 30mA, R
DC
55Ω,
1kHz Test Frequency 400kHz
Fastron/SMCC-152K
Abracon/AIAP-01-152K
ACT/DD152K-R
Fastron/SMCC-821K
Abracon/AIAP-01-821K
Panasonic/ELJ-FB821JF
R101A-C
1MΩ 1MΩ
±5%, 1/4W,
max working voltage600VDC (1), (3)
510VAC
(820VDC)
510VAC
(820VDC)
For indoor use, 4500A surge current,
8x20µs, 2 times (4)
Panasonic/ERZ-V14D821
Joyin/JVR14S821K87
Panasonic/ERZ-V14D821
Joyin/JVR14S821K87
RV101A-
C
510VAC
(820VDC)
510VAC
(820VDC)
For outdoor use, 6500A surge current,
8x20µs, 2 times (4)
Panasonic/ERZ-V20D821
Joyin/JVR20S821K11
Panasonic/ERZ-V20D821
Joyin/JVR20S821K11
NOTES:
1. For 277VAC nominal line voltage operation, the voltage rating of these components must be increased.
2. In some applications, fuses might not be required. Consult applicable safety standards.
3. The voltage rating of R101A-C can be achieved by using two 510kΩ resistors in series, each with a working voltage rating of at
least half of the value listed above. For earth-return coupling, the peak power and peak voltage ratings of R101A-C must be chosen
to meet high-pot testing requirements of the application.
4. The voltage rating indicated is necessary to prevent damage to the varistor should the neutral (or earth) connection be lost while all
three phases are connected and live. For earth-return coupling, high-pot testing must be performed prior to installation of these
varistors. High-pot testing between line and earth is usually performed at voltages above the varistor clamp voltage, and the test
will fail if the varistors clamp during testing. In addition, a DC high-pot tester must be used to avoid excess current flow through
C101.