PL 3120/PL 3150/PL 3170 Power Line Smart Transceiver Data Book 115
Table 4.5 Line-to-Earth, Transformer-Isolated Coupling Circuit Component Values
Value Required Specifications Example Vendors / Part numbers
Comp
C-band
100-
120VAC
C-band
200-
277VAC
C-band 100-120VAC C-band 200-277VAC
C101 0.068µF
120VAC
0.033µF
300VAC
±10%, X2 type (1) IllinoisCap/683MKP275KB
AID Electronics/
MEX683K275AC
Evox-Rifa/
PHE840EA5330KA02
C102 1.0µF 1.0µF
±10%, 63VDC, metallized film
Arcotronics/
R82DC4100AA60J
Surge /SRMA100V105K
Arcotronics/
R82DC4100AA60J
Surge /SRMA100V105K
C103
120µF 120µF
±20%, 16VDC, aluminum electrolytic,
0.35Ω ESR @100kHz/20C,
290mA
RMS
ripple current @105C
Nichicon/UHE1C121MED
Fenghua/
8121LCMAA11LY
Nichicon/UHE1C121MED
Fenghua/
8121LCMAA11LY
D101 1A 1A
Reverse breakdown 50VDC, forward
voltage 1.3V @1A/25C, surge current
30A for 8.3ms, reverse recovery
200ns, reverse current 100µA @100C,
typical capacitance 40pF @4V
Fairchild/1N4937
Vishay/1N4935-E3
Fairchild/RS1D
Fairchild/1N4937
Vishay/1N4935-E3
Fairchild/RS1D
D102 1A 1A
Reverse breakdown 50VDC, forward
voltage 1.0V @1A/25C, surge current
30A for 8.3ms, reverse recovery 25ns,
reverse current 100µA @100C, typical
capacitance 40pF @4V
Fairchild/ES1B
Vishay/ES1D-E3
OnSemi/MUR120G
Fairchild/ES1B
Vishay/ES1D-E3
OnSemi/MUR120G
F101
6A or 6.3A
120VAC
6A or 6.3A
277VAC
Time-lag, (2) Wickmann/3741630041
Hollyfuse/5RT-063H
Bel/MRT6.3
L102 5.6µH 27µH
±10%, Imax 700mA, R
DC
0.25Ω
Abracon/AIAP-01-5R6K
Shinhom/LGA0512-5R6K
CTC Coils/
EC385R6K-506409-T
Taiyo Yuden/
LHL08TB270K
Abracon/AIAP-01-270K
Shinhom/LGA0512-270K
L103 820µH 820µH
±10%, Imax 30mA, R
DC
55Ω,
1kHz Test Frequency 400kHz
Fastron/SMCC-821K
Abracon/AIAP-01-821K
Panasonic/ELJ-FB821JF
Fastron/SMCC-821K
Abracon/AIAP-01-821K
Panasonic/ELJ-FB821JF
R101
10MΩ
200VDC
10MΩ
450VDC
±5%, 1/4W, (3)
N/A N/A For indoor branch circuits no component
is required
N/A N/A
120VAC 300VAC Power entry - use AC gas discharge tube
(4)
Littlefuse/AC240L
PROTECT
120VAC 300VAC Outdoor - use AC gas discharge tube (4) Littlefuse/AC240L
T101 12uH-leakage
transformer
See Appendix C See Appendix C See Appendix C
NOTES:
1. An X2 capacitor is required for adequate surge immunity in branch circuit applications.
2. In some applications, a fuse might not be required. Consult applicable safety standards.
3. The working voltage rating of R101 can be achieved by using two 5.1MΩ resistors in series, each with a working voltage rating of at
least 1/2 of the value listed above. Also peak power and voltage ratings of R101 must be chosen to meet the high-pot testing
requirements of the application.
4. High-pot manufacturing tests must be performed prior to installation of this gas discharge tube. High-pot testing between line and
earth is usually performed at voltages above the gas tube arc-over voltage, and the test will fail if the gas tube arcs during testing.
In addition, a DC high-pot tester must be used to avoid excess current flow through C101.