PL 3120/PL 3150/PL 3170 Power Line Smart Transceiver Data Book 107
Table 4.1 Coupling Circuit Selection Guide
Example
Connection
Type
Line
Voltage
Isolated/
Non-Isolated
Freq.
Band
Typical
Application(s)
Page
C
Consumer, residential devices world-wide,
Commercial devices in CENELEC countries
1 1-Phase L-N 240VAC/DC Non-Isolated
A
Electric utility meters world-wide
108
C
Consumer residential devices world-wide,
Commercial devices in CENELEC countries
2 1-Phase L-N 240VAC/DC Isolated
A
Utility devices world-wide
110
3 1-Phase L-E 100-277VAC Non-Isolated C
Commercial devices in North America
112
4 1-Phase L-E 100-277VAC Isolated C
Commercial devices in North America
114
C
Commercial panel devices world-wide
5 3-Phase 100-277VAC Non-Isolated
A
3-Phase utility devices world-wide
116
C
Commercial panel devices world-wide
6 3-Phase 100-277VAC Isolated
A
3-Phase utility devices world-wide
118
C
Consumer, residential devices world-wide,
Commercial devices in CENELEC countries
7 1-Phase L-N
Floating
240VAC/DC Non-Isolated
A
Utility devices world-wide
120
8 Power Supply
Plus Coupler
90-240VAC Isolated
C
Consumer, residential devices world-wide,
Commercial devices in CENELEC countries
122
9 Low-Volt AC 48Vpk Non-Isolated C
HVAC and irrigation devices world-wide
124
10 Low-Volt AC 48Vpk Isolated C
HVAC and irrigation devices world-wide
126
11 Low-Volt DC 48Vpk Non-Isolated C
Automotive wiring world-wide
128
12 Retired
N/A
13 Long-Haul 240VAC/DC Isolated C
300m-20km dedicated lines world-wide
See Note
14 Current-loop N/A Isolated C
Airport lighting devices world-wide
See Note
15 1 or 2 of
3-Phase L-E
100−240VAC Isolated
C
Commercial devices in North America
See Note
16 UL 197 L-E 100−240VAC Isolated C
Commercial cooking equipment in North America
See Note
Note: Contact the Echelon LonSupport group for additional information on this coupling circuit.