Specifications
Chapter 3 – Input/Output Interfaces
94 PL 3120/PL 3150/PL 3170 Power Line Smart Transceiver Data Boo
k
OUTPUT
SYNC INPUT
TIME
t
sod
START OF
io_out()
INTERNAL
COUNT
BEGINS
END OF
io_out()
START OF
io_out()
OUTPUT
INACTIVE
t
fod
t
fout
t
win
t
ret
Timer/Counter 1
Timer/Counter 2
IO10
IO9
IO8
IO0
IO1
IO2
IO3
IO4
IO5
IO6
IO7
mux
Output
Sync
Input
Optional Pull-Up ResistorsHigh Current Sink Drivers
IO11
Symbol Description Min Typ Max
t
fout
Function call to start of timer — 96 µs —
t
fod
Function to output disable — 82.2 µs —
t
sod
Active sync edge to output toggle 550 ns — 750 ns
t
win
Sync input pulse width (10MHz) 200 ns — —
t
ret
Return from function — 13 µs —
Figure 3.49 Edgedivide Output Object