Specifications
USER’S HANDBOOK
Click on Reset C
lock to reset the data, the following screen will be displayed (Ref. Fig. 46).
The value of the computer clock will be downloaded to the ELT internal real time clock.
Reset Clock Screen
Figure 46
Note: This task is mandatory after a battery servicing process because the time and date are
lost during this task (no back up power for the real time clock)
Note: This task can be performed at any time if a time discrepancy is discovered during
maintenance process. It will copy the local computer time to the ELT transmitter.
Clicking on M
aintenance Off will open an auto save box requesting to enter the ELT serial
number and a remark for the follow up of the test report.
If the P/N is available in the ELT transmitter it will be used to create the test report file name.
If not, the operator will select the correct one in the presented rolling list. Maintenance mode
remains active and further ELT accesses are possible.
Page 75
Mar
. 08/12