During the test, the following screen (Ref. Fig. 33 or 34) is displayed.
Result of ELT Test (ADT 406 AF/AP)
Figure 33
Note: For the ADT 406 AF/AP and ADT 406 AP ELT models the test bench acquires the model
type, the P/N and the Revision index directly from the ELT when available (in the Fig.
33 example the model type is ADT 406 AF/AP, P/N is 01N65900 and the revision index
is G)
Note: After the first Cospas-Sarsat transmission burst reception, the field “Tr” is blank
because the test bench needs at least two consecutive transmissions for the correct
calculation of these parameters. If the customer tries to save or print this un-
complete screen the test report will indicate “Synchronization in progress”.
Note: The available limits (ELT specification + test bench measurement tolerances) for each
parameter can be displayed easily on line. When the operator puts the pointing arrow
on the parameter box, the values of the assigned limits are displayed for about 3s.
These limits values are customized to each ELT model.
Note: Parameters Limits are automatically assigned to each ELT model. Configuration file
containing this information is called “Specification”. Its release # is displayed on the
first STB-06 test bench software (see fig. 12). Updated configuration files (does not
impact test bench software release) can be downloaded from ELTA website under
secure access (login & password). Contact ELTA as necessary.