Specifications
USER’S HANDBOOK
(c) RF
Test
This test task does not apply to Prog. Box equipment P/N 95N6089 as it is not a transmitter.
To perform this task the ELT transmitter or Programming Box or CodADT tool must be connected to
the Test Interface Device PROG connector on one side with the relevant encoding cable:
Note: This connection does not apply to ADT 406 S, as there is no connector on its front
panel):
For the A06V2 ELT transmitter, connect the P/N 96N9029 extension cable with the P/N 96N9028
cable. They are connected to the TC connector (ELT side) and to the PROG connector (Test
Interface Device side),
For all ADT406 ELT models, except ADT 406 S, use the P/N 02N65746 cable connected to the
ELT REMOTE CONTROL connector (ELT side) and to the PROG connector (Test Interface Device
side),
For the A06 or A06V1 or A06T or S06 ELT, use the P/N 93N6222 cable connected to the TC
connector (ELT side) and to the PROG connector (Test Interface Device side),
The P/N 94N6460 RF cable must be connected to the ANT (TNC) for the model A06 or A06V1 or
A06T or S06 or to EXT. ANT. (BNC) connector of the model ADT 406,
Note: When this RF cable is connected there is no RF radiation. The test can be performed
without any shielded room requirement.
On the test bench main menu screen (Ref. Fig. 12) Click T
est to switch the test bench to RF test
mode. The following empty test screen (Ref. Fig. 31) is then displayed after click on Test O
n.
Note: The test bench will automatically detect which ELT model is under test and will display
this information on the right of the screen.
Note: The model ADT 406 operates on 406.028 MHz.
Note: The model A06xx/S06 operates on 406.025 MHz.
Click Test ON Su
rvival to start the RF test with ADT 406 S model and follow instructions on the
screen,
Click Test O
N to start the RF test with any other ELT models and follow instructions on the
screen.
Page 55
Mar
. 08/12