Specifications

USER’S HANDBOOK
2
Beacon ID creation or update
To perform this task the ELT transmitter or Programming Box or CodADT tool must be connected to
the Test Interface Device PROG connector on one side with the relevant encoding cable:
For the Programming Box (Prog. Box) of the ELT model A06V2, use the P/N 96N9028 cable,
Note: Connect the Jaeger connector only to the Programming Box side and connect the
other end to the PROG. Connector (Test Interface Device side) when the software asks
to “Turn ON the beacon”.
For the A06V2 ELT transmitter, connect the P/N 96N9029 extension cable with the P/N 96N9028
cable. They are connected to the TC connector (ELT side) and to the PROG connector (Test
Interface Device side),
For the ADT406 ELT or CodADT tool, use the P/N 02N65746 cable connected to the ELT
REMOTE CONTROL connector (ELT side) and to the PROG connector (Test Interface Device
side),
Note: the software automatically detects the CodADT tool.
For the A06 or A06V1 or A06T or S06 ELT, use the P/N 93N6222 cable connected to the TC
connector (ELT side) and to the PROG connector (Test Interface Device side),
Click on Create A
06xx/S06 to select a new or an other C/S identification for the A06xx or S06 ELT.
To create or update to a new C/S identification for Programming Box, click on Create PROG
BOX.
To create or update to a new C/S identification for ADT 406 AF/AP, click on Create AD
T 406 AF/AP.
To create or update to a new C/S identification for ADT 406 AF/AP-H, click on
Create ADT 406 AF/APH
.
To create or update to a new C/S identification for ADT 406 AP, click on Create ADT 406 AP
.
To create or update to a new C/S identification for ADT 406 S, click on Create ADT 406 S
and use
the CodADT tool interface to receive the Activation/Identification module.
The following screen (Ref. Fig. 18) is displayed.
Parameters in Box 1; 2; 3; 4; 5 are related to Cospas-Sarsat Identification and modify the Beacon
ID content.
Parameter on Box 6 is related to Cospas-Sarsat but is “for information only” and consequently does
not appear in the Beacon ID content (so beacon ID content is not impacted nor modified by this
information).
Parameter in Box 7 is only operational for one version of ELT: the model ADT 406 AF/AP. By default
we select “High” value and we recommend keeping this selection.
Note: Previously the power was indicated as 20 and 23 dBm, now ELTA modified the display
and we are using Low (corresponding to former 20 dBm) and High (Corresponding
to former 23 dBm). This presentation is more versatile.
Page 41
Mar
. 08/12