Specifications

USER’S HANDBOOK
C. List of ELT model addressed by STB-06 test bench
ELT model ELT Type ELT P/N Rev. (Amendment)
ADT 406 AF/AP Automatic Fixed 01N65900 A to K
ADT 406² AF/AP Automatic Fixed 01N65900 L and above
ADT 406² AF/AP-H Automatic Fixed 01N65901 A and above
ADT 406 AP Automatic Portable 01N65910 A and above
ADT 406 S Survival 01N65920 A and above
A06 Automatic Portable 9260065 A and above
A06V2 Automatic Portable 95N6088 A and above
Prog.Box To be use with A06V2 95N6089 A and above
A06T Automatic Portable 94N6576 A and above
A06GE Automatic Portable 93N6205 A and above
A06M Automatic Fixed 02N62322 A and above
S06 Survival 94N6576 A and above
D. General characteristics
(1)Environment
Operating temperature with the case open : 5°C to +35°C.
Storage temperature with the case closed : 0°C to +55°C.
Humidity without condensation : 20% to 80%
(2)Transport case closed (STB-06-A only)
When the transport case is closed, the test bench components are protected against:
- Dust. All the test bench components are protected against harmful deposits,
- Impacts (0.225 joule). The case can withstand a weight of 150 grams dropped from a height 15
cm.
The case is designed to withstand vibrations with a frequency of 5 to 150 Hz and an acceleration of
1G on all 3 axes.
(3)Transport case open
When the transport case is open, the test bench components are not protected or immobilized.
It is also the case for the STB-06-LA version.
Page 9
Mar
. 08/12