Datasheet
Table Of Contents
- General
- Features
- T-200 Specifications
- General Performance
- Operating Temperature : -20℃ ~ 60℃
- Operating Humidity : 0 ~ 95% RH (Non-condensing)
- Operating Environment : Residential, Commercial spaces
- Storage Temperature : -30℃~70℃
- CO₂ Measurement
- Sensing Method : NDIR (Non-dispersive Infrared)
- Measurement Range : 400 ~ 2,000
- Accuracy : ± 50ppm ± 3%of reading
- Response Time(1/e) : 40 seconds (c.f. T90 : 65 seconds)
- Signal Update : 3 seconds
- Electrical Data
- Power Input : 5.0VDC ± 5%(2)
- Current Consumption: Normal mode : 22mA, Peak : 250 mA
- Pin Map of J1 Side hole.
- ※ J1 Side Hole : 1.27mm pitch
- UART
- 38,400BPS, 8bit, No parity, 1 stop bit, TTL Level Voltage
- I2C
- Pin Map of J2 Board to Board Connector.
- ※ B-to-B Connector mating should be enhanced with additional Locking method.
- (T-200 has two of screw type-locking hole - 2Ø U-type hole)
- UART Descriptions
- Data Format
- I2C Communication (Only Slave Mode Operation)
- 2. Proper ESD protection during handling is important to avoid electrostatic defect occurrence.
- The storage of sensor should be insulated as well
ELT SENSOR Corp.
2 | Page
T-200 Specifications
General Performance
Operating Temperature : -20℃ ~ 60℃
Operating Humidity : 0 ~ 95% RH (Non-condensing)
Operating Environment : Residential, Commercial spaces
Storage Temperature : -30℃~70℃
CO
₂
Measurement
Sensing Method : NDIR (Non-dispersive Infrared)
Measurement Range : 400 ~ 2,000
Accuracy : ± 50ppm ± 3%of reading
Response Time(1/e) : 40 seconds (c.f. T
90 : 65 seconds)
Signal Update : 3 seconds
Warming-up Time : < 6 seconds (for Operation), 5 minutes (for Accuracy)
Electrical Data
Power Input : 5.0VDC ± 5%
(2)
Current Consumption: Normal mode : 22mA, Peak : 250 mA
Pin Map of J1 Side hole.
※ J1 Side Hole : 1.27mm pitch
Pin No.
T-200
1
VDD (+5V VCC)
2
GND
3
TTL-RXD( ← CPU of Master Board )
4
Reserved
5
TTL-TXD( → CPU of Master Board )
6
ACDL(Automatic Calibration)
7 Reserved
8
I2C SCL
9
I2C SDA
10
MCDL(10 min. Manual Calibration)