Datasheet
Table Of Contents
- General
- Features
- T-200 Specifications
- General Performance
- Operating Temperature : -20℃ ~ 60℃
- Operating Humidity : 0 ~ 95% RH (Non-condensing)
- Operating Environment : Residential, Commercial spaces
- Storage Temperature : -30℃~70℃
- CO₂ Measurement
- Sensing Method : NDIR (Non-dispersive Infrared)
- Measurement Range : 400 ~ 2,000
- Accuracy : ± 50ppm ± 3%of reading
- Response Time(1/e) : 40 seconds (c.f. T90 : 65 seconds)
- Signal Update : 3 seconds
- Electrical Data
- Power Input : 5.0VDC ± 5%(2)
- Current Consumption: Normal mode : 22mA, Peak : 250 mA
- Pin Map of J1 Side hole.
- ※ J1 Side Hole : 1.27mm pitch
- UART
- 38,400BPS, 8bit, No parity, 1 stop bit, TTL Level Voltage
- I2C
- Pin Map of J2 Board to Board Connector.
- ※ B-to-B Connector mating should be enhanced with additional Locking method.
- (T-200 has two of screw type-locking hole - 2Ø U-type hole)
- UART Descriptions
- Data Format
- I2C Communication (Only Slave Mode Operation)
- 2. Proper ESD protection during handling is important to avoid electrostatic defect occurrence.
- The storage of sensor should be insulated as well
ELT SENSOR Corp.
1 | Page
General
T-200 series is the world’s smallest CO2 sensor
module. Its Persistent Stability and Temperature
Effect Resistance besides easy management are
much favored by customers in stocks raising,
greenhouse, scientific projects, etc.
Features
• Non-Dispersive Infrared (NDIR) technology used
to measure CO₂ levels.
• .The world’s smallest size
• .Pre-calibrated
• Available output : TTL-UART, I2C
(PWM/Analog Voltage option)
•.Gold-plated sensor provides long-term
calibration stability.
• Installed Calibration function
•ACDL (Periodical Automatic Calibration) and
MCDL (Non-Periodical Manual Calibration)are
available..
.
• Size : 19.4mmx30mmx10.3mm
• Weight : 5 grams
ELT Sensor
Data Sheet for T-200
Ver
1.2_Conrad