User Manual

Model UFT PCBA manual
General
The Model UFT printed circuit board assembly (PCBA) contains a frequency hopping spread spectrum radio
operating in the 902.4-927.6 MHz ISM frequency band and a 451.35 MHz FCC Part 90 licensed radio. It also
contains a pre-certified Bluetooth module used for communication with user’s Bluetooth enabled portable
device. When the UFT module is installed in its plastic housing it forms a pass-through device used to
interrogate Elster Solutions metering devices that are currently installed. Installations of multiple metering
devices comprise part of an Advanced Metering Infrastructure (AMI) system that utilizes a proprietary network
architecture and protocol devised by Elster Solutions. The UFT is used by the user to allow communication with
devices within this network architecture.
Device specifications
Table 1: 900 MHz Radio Specifications for 25-Channel 250 mW EA Operation
Classification
Frequency Hopping Spread Spectrum
Maximum Output Power
250 mW
Operating Frequency Band
902.4
927.6 MHz
Number of Channels
25
Channel Spacing
400 KHz
Mode
Data Rate
35.56 kbps
142.22 kbps
Occupied Bandwidth – 20dB
250 KHz < BW < 400 KHz
250 KHz < BW < 400 KHz
Occupied Bandwidth – 99%
250 KHz
< BW < 400 KHz
250 KHz < BW < 400 KHz
Channel Dwell Time
< 0.4 seconds within a 10 second period
Table 2: 900 MHz Radio Specifications for 64-Channel 250 MW NGC Operation
Classification
Frequency Hopping Spread Spectrum
Maximum Output Power
250 mW
Operating Frequency Band
902.4
927.6 MHz
Number of Channels
64
Channel Spacing
400 KHz
Mode
NGC
Data Rate
50, 150, 200 kbps
FSK Occupied Bandwidth – 20dB
100 KHz < BW < 400 KHz for 50/150/200 kbps data rates
FSK Occupied Bandwidth – 99%
100 KHz < BW < 400 KHz for 50/150/200 kbps data rates
GFSK Occupied Bandwidth – 20dB
100 KHz < BW < 400 KHz for 50/150/200 kbps data rates
Channel Dwell Time
< 0.4 seconds within a 20 second period