User's Manual
SRP OPERATION CHAPTER 3
Page 14 Short Range Programmer VRT—User Guide
P/N 52806T100 Rev 1 April 2003
•
AMCO Automated Systems
• For V9 and VRT transponders which were interrogated in
Find mode the compensation factor ratio also displays on the
lower line:
2. If the serial number represents the target transponder, go to step 4.
3. If Find mode was not used or the serial number displayed is not the
serial number of the target transponder, enter the desired serial
number.
• To enter serial number, press the ENTER button until the cursor
(flashing dark box) appears over the first digit of the Serial No.
input field. Enter the serial number. Press the ENTER button
when completed.
4. Read the meter conventionally (visually, from the mechanical index).
• The SRP display will also show the CF Ratio (where applicable).
5. Enter the meter index value using the SRP keypad.
• This field requires 7 digits. Read and enter index value from left
to right, just as you would normally read and write any numerical
value. Include as many leading zeroes as are needed to fill
positions to the left of the meaningful digits.
6. Enter the compensation factor using SRP keypad. (V9 and VRT
transponders)
• CF Ratio obtained in step 4 (where applicable).
• To enter the CF value, press the ENTER button until the cursor
(flashing dark box) appears over the CF Ratio numerator (top
number) and/or denominator (bottom number). Enter the correct
value. Press the ENTER button when completed.
7. Press either of the two INT (interrogate) buttons.
• This programs the baseline meter index value and compensation
factor (v9 and VRT) into the transponder memory.
• If programming is successful
, the SRP will display the
“PROGRAM VERIFIED” message.
• If programming is NOT successful
, the screen will display the
“PRGRM COMPARE ERROR” message.
PROGRAM METER INDEX
Serial No.. 03571641
Index No... 00001348
CF Ratio... 001/001