Installation Instructions
Water 4.0 module 2 IL42-5050B
REMOTE INSTALLATION INSTRUCTIONS
WALL MOUNT
The Honeywell Water 4.0 module can be mounted on a wall close to the water meter. To assist placing the enclosure on the
hanging screw, the enclosure has hash marks that will help you properly align the module.
The cable from the Honeywell Water 4.0 module and the water meter register should not exceed 100 feet (30 meters).
1 Remove the remote mount cover from the Honeywell Water 4.0 module.
CAUTION
!
Be sure to connect the cables correctly. Failing to properly connect the cables may prevent the module from installing
correctly. For information on proper connections, see “Connection instructions” on page 1.
2 For proper operation of the module, connect the cables as described in “Connection instructions” on page 1.
- If you do not have an inline connector, splice the cables from the Honeywell Water 4.0 module to the water meter
register cable using weatherproof gel caps (for example, 3M style UY2 IDC). Be sure to follow the manufacturer’s
directions for wire preparation when using gel caps.
Insert the cable back into the Honeywell Water 4.0module, making sure to provide strain relief for the cable. Be sure to
securely fashion the cable by using the cable tie, as illustrated in the next figure.
CAUTION
!
Be sure that the arrows are as closely aligned as possible before mating. Failing to properly align the arrows may result in
damage to the connector, requiring a replacement of either the connector or the module itself.
- If you have an inline connector, align the arrows on both connector ends. Press firmly to fully mate the connectors (see
next figure).
Cable tie
Preliminary