REX Meter
Technical Manual B Display
Figure B-11. Sample network registration status sample display
Table B-2. Network registration status sample display description
Code Description
2 The number of communication “hops” between the REX meter and
the collector. In the example, the 2 indicates that the REX meter
communicates with the collector through one other REX meter.
r Indicates that the REX meter is registered with a collector.
2049 The last 4 digits of the collector’s LAN ID.
• In REX meter release 1.0, the last 4 digits are in hexadecimal
format.
• In REX meter releases 2.0 and higner, the last 4 digits are in
decimal format.