User's Manual
Table Of Contents
- Introduction
- Product Description
- Operating Instructions
- Outputs
- Testing
- Installation and Removal
- Glossary
- Display
- Nameplate Information
- Wiring Diagrams
- Technical Specifications
3UHOLPLQDU\
Contact Elster Electricity for information
30 November 2006 3-5
REX Meter
Technical Manual 3 Operating Instructions
Clear Billing Data
This procedure copies the current billing data to the demand reset data area and
then zeros the REX meter’s current billing register. The demand reset data area
copy can be read by MAS. The clear current billing data is performed
immediately when the REX meter receives the command over the 900 MHz
network.
Clear Data
This procedure is used in the meter shop before installing the meter in the field.
Using Metercat support software and an optical probe placed on the optical
port, the command does the following:
■ clears current and previous billing data
■ clears rates and rate overrides
■ clears the 32-day calendar
■ clears node scan responses
■ clears LAN registration and status information
■ clears load profiling data
■ clears the power fail data save area
■ resets kWh DEL and kWh REC lines on the option header
■ resets the demand threshold relay
■ closes the service control switch, if installed