User's Manual

A3 ALPHA Meter/Collector
July 2004 Product Guide
3
Figure 3. A3 ALPHA meter with ITM3 RJ-11 cable
Metercat Programming Note
To have the A3 ALPHA meter function properly as a data collector in the
EnergyAxis System, it is important that the meter be programmed correctly
using Metercat
. In the Remote component tab in Metercat, be sure that the fol-
lowing options are set:
Port 1 usage is set to internal modem.
Port 2 usage is set to direct connect.
On the Port 1 Modem tab, enable line sharing (the Enable Line Sharing
box is checked).
On the Port 2 Direct Connect tab, the bit rate is set to 9600.
The other options can be set as desired. For more information on using Meter-
cat, see the Metercat documentation.
Metering Software and
System
Metercat
The A3 ALPHA meter/collector requires Elster Electricity Metercat support soft-
ware release 1.4 or later. Metercat offers the following features:
program development to create user-defined configuration data
meter programming to send user-defined configuration data or com-
mands to the meter
meter reading to receive data that has been stored by the meter
diagnostic read including ILC1 option board and LAN status
ability to perform tasks related to replacing a collector
EnergyAxis Metering Automation Server
The EnergyAxis Metering Automation Server (MAS) reads meters over telephone
or wireless networks. Using MAS, meter readings can be scheduled or per-
formed on-request from the browser-based user interface. MAS allows all billing
data to be read from the meter; this includes data from the A3 ALPHA meter
and from each REX meter registered with the ILC1 option board. Billing data
from the A3 ALPHA meter includes multi-channel interval data, consumption,
demand, time-of-use registers as well as meter status flags. REX meter data can
be read from the stored data in the collector or on-request by using MAS to
communicate through the collector to the individual REX meter.
INT MOD ITM3