User's Manual

Chapter 4 Operation
G_NT The transponder has replied with a good read, no tamper condition.
G_NR The transponder has replied with a good reading and is showing a tamper
status, but the MMI is not going to reset the tamper condition as controlled
by the system configuration. The system configuration may be changed in
the System Setup menu, or by changing the values in the Guide file.
G_TR The transponder has replied with a good reading and was showing a
tamper status, and the MMI successfully reset the prior tamper condition.
G_T_RF The transponder has replied with a good reading and is showing a tamper
status, but the MMI cannot reset the tamper condition, possibly because
the transponder is still in a position that is causing the tamper status.
G_T_RP The transponder has replied with a good reading and is showing a tamper
status, but the MMI was not able to verify if the tampered condition was
reset. This may occur if the MMI goes out of range of the transponder
while still trying to interrogate it to verify the tamper status. The reading
for the transponder is good, but the tamper condition may or may not still
exist.
NO_RD The transponder has been polled, but the minimum number of receiver
channels did not received enough good data to pass the channel matching.
This usually occurs when a transponder is still too far away from the MMI.
BAD_RD The transponder has been polled and the receiver was able to lock on to
the
incoming data, but the BCH error detection has failed. This may occur if
the MMI is in an area of strong interference, and is usually corrected when
the MMI gets closer to a transponder.
BAD_MR The 3rd generation transponder has replied with an indication that the
meter reading checksum has failed. This could be due to a new battery
being inserted in the transponder, or due to a malfunction. The transponder
should be checked and reprogrammed. The meter reading should not be
trusted.
BAD_ID The 3rd generation transponder has replied with an indication that the
serial
number checksum has failed. This could be due to a new battery being
inserted in the transponder, or due to a malfunction. The transponder
should be checked and reprogrammed. The meter reading should not be
trusted.