User's Manual

Table Of Contents
EA Mobile User Guide
7. Command mode
79
Output Code is a code used by the EA_Mobiles processor to classify read
conditions in the output file written to the USB flash drive when a route is
completed and saved.
Detailed description describes the conditions identified by each status type,
and in some cases, possible causes and solutions.
Status Code Simple description Output
Code
Detailed description
UNINT Uninterrogated 10 The endpoint has never been interrogated because it does not appear
within the interrogation window.
G_NT Good, not tampered 01 Endpoint has replied with a good read, no temper condition reported.
G_NR Good, tampered, not reset 03 Endpoint has answered with a good reply and is showing a tamper status
G_TR Good, tamper reset 07 Endpoint has answered with a good replay and was showing a tamper
status. EA_Mobile has successfully reset tamper condition.
G_T_RF Good, tamper reset failed 0B Endpoint has answered with a good reply and is showing a tamper status
but the EA_Mobile cannot reset the tamper condition (possibly because
the endpoint is still in the condition that triggered the tamper message).
G_T_RP Good, tamper reset pending 0F Endpoint has answered with a good reply and is showing a tamper status
but the EA_Mobile was not able to verify the tamper condition was reset.
This may occur if the EA_Mobile goes out of range while interrogating and
before verifying the tamper reset.
NO_RD EA_Mobile received no reply
from endpoint
20 Endpoints which have not processed all outstanding command or the
endpoint failed to read for some reason.
BAD_RD Bad read 40 Endpoint has been interrogated and the receiver was able to lock on to the
incoming data but the BCH error detection test has failed. This may occur if
the EA_Mobile is in an area of strong interference and is usually corrected
when the EA_Mobile gets closer to the endpoint.
BAD_MR Bad meter reading
checksum
41 Endpoint has answered with an indication that the meter reading
checksum has failed. This may be the result of a temporary power
fluctuation. The endpoint should be checked and reprogrammed.
Manually verify and enter meter reading.
BAD_ID Bad serial number
checksum
42 Endpoint has answered with an indication that the serial number
checksum has failed. This may be the result of a temporary power
fluctuation. The endpoint should be checked and reprogrammed.
Manually verify and enter meter reading.
BAD_B2 Both checksums bad 43 Endpoint has answered with an indication that both the meter reading and
serial number checksums have failed. This may be the result of a
temporary power fluctuation. The endpoint should be checked and
reprogrammed. Manually verify and enter meter reading.
N_T_RP No read, tamper reset
pending
2F Endpoint has answered with a good reply and is showing a tamper status
but during the tamper reset verification, the endpoint reply resulted in a
NO_RD status. The tamper condition may or may not still exist. (See NO_RD
description.)
B_T_RP Bad read, tramper reset
pending
4F Endpoint has answered with a good reply and is showing a tamper status
but during the tamper reset verification, the endpoint reply resulted in a
BAD_RD status. The tamper condition may or may not still exist. (See
BAD_RD description)