Table of Contents Introduction - System Overview ............................................................................. 3 Warranty ..................................................................................................... 5 Acronyms ..................................................................................................... 7 Product Selection Guide ................................................................................. 10 Preparation - Safety Precautions ...............
Introduction - System Overview Tailored for PQ Analysis at any location, the Portable BLACKBOX has been especially designed to address the needs of Site Engineers, Electrical Consultants & Utilities: No Missed Events Quick & Simple Setup Remote Connectivity Plug & Play Empowered by the patented PQZIP compression technology, the G4500/G3500 can store up to a thousand times more than other typical file formats.
EVERYTHING YOU NEED IN A PORTABLE POWER QUALITY SOLUTION & MORE 1 X Custom Clamp 3-Flexible Current Probes 5 X Voltage Leads (Automatically Detected) 2 X DC Voltage Cords (G4500) Durable Carrying Case Rechargeable Power Supply (2 Hours Standby) Wireless Network (G4500) PQSCADA / Investigator Software CD Mobile Analysis Lab SEE ALSO: Warranty Acronyms Product Selection Guide 4 ELSPEC G4500 & G3500 Portable Power Quality Analyzer USER & INSTALLATION GUIDE
Warranty Each Elspec product is under warranty to be free from defects in material and workmanship under normal use and service. The warranty period is for one year and commences on the date of shipment. Parts, product repairs, and services are under warranty for 90 days.
SEE ALSO: System Overview Acronyms Product Selection Guide 6 ELSPEC G4500 & G3500 Portable Power Quality Analyzer USER & INSTALLATION GUIDE
Acronyms The following acronyms are being used within this document: ACRONYM 7 DEFINITION PQ Power Quality V Voltage I Current AC Alternating Current DC Direct Current F Frequency VN Voltage Neutral IN Current Neutral A Ampere CT Current Transformer PF Power Factor PT100 Platinum Resistance Thermometers PU Per Unit PT Potential Transformer (transformation ratio in both magnitude and phase) CT Current Transformer HV High Voltage MV Medium Voltage LV Low Voltage THD To
ACRONYM LAN Local Area Network WAN Wide Area Network ADSL Asymmetric Digital Subscriber Line CF Compact Flash OLP OLE for Process Control (set of connectivity standards for industrial automation) OPC Open Connectivity (formerly OLE for Process Control) TCP Transport Control Protocol FTP File Transfer Protocol DHCP Dynamic Host Configuration Protocol DNP3 Distributed Network Protocol PPP Point to Point Protocol PAP Password Authentication Protocol CHAP Challenge Handshake Authenticat
ACRONYM DEFINITION ELSPEC G4500/G3500 BLACKBOX DEVICE & ACCESSORIES BB BLACKBOX G4500 / G3500 BLACKBOX Portable Power Quality Analyzers G4150 Mobile Analysis Lab PQA Power Quality Analyzer R/O Perform Read Only Functions Within the BLACKBOX Interface R/W Perform Read & Write Functions Within the BLACKBOX Interface RTC BLACKBOX Internal Real Time Clock DSP Digital Signal Processing Module (Located Internally) PQZIP Power Quality Data Compression & Archive File Format PQSCADA Power Quality
Product Selection Guide The product selection guide will assist you in choosing the optimal Portable PQ Analyzer that will suit your needs & requirements. The BLACKBOX device series includes 2 products, namely the G4500 & G3500. They are mainly differentiated by their measurement capabilities, storage capacity, PQ analysis & communication ports.
CAPABILITIES PRODUCT SERIES G4500 G3500 With Ethernet Synchronization 50 50 With GPS Synchronization 1 1 32 GB 32TB2 256 MB 256 GB2 19.5/16.3µs 39/32.
CAPABILITIES PRODUCT SERIES G4500 G3500 COMMUNICATION CONTROL Web Server Comprehensive web server for local & remote realtime monitoring & control FTP Server Standard protocol for main storage memory PORTS Ethernet Ports RS-232, RS-485 Ports Wi-Fi Communications (802.11g) 2 LAN & 1 WAN (Integrated Router, NAT & Firewall) 1 LAN 1 1 1 (With Integrated Antenna) ___ LAN 1 Communication Protocols Power Over Ethernet (PoE- In)3 TELNET, OPC, SMTP Client According to 802.
MULTI IO DIGITAL INPUTS Channels 4 Sampling 800 Hz @ 50Hz (16 spc) 960 Hz @ 60Hz (16 spc) Range Pulse Type Functionality Isolation Connector 0 – 220 VDC 0->1->0, 1->0->1, KYZ Triggers based on events / Energy pulse counting 125V RELAY OUTPUT Channels 1 Max Voltage 277 VAC Max Current 5A / 250VAC 10A / 110VAC 5A / 30VDC Max Reaction time 10ms Max Drop-out time 4ms Output Resistance 50MΩ EFFECTIVE BITS DISCLAIMER: OUTLINED CAPABILITIES SUBJECT TO CHANGE EQUIVALENT MEMORY NEEDED WITHOUT PQZI
Preparation - Safety Precautions WARNINGS REVIEW THE ENTIRE MANUAL BEFORE USING THE INSTRUMENT AND ITS ACCESSORIES OBSERVE ALL WARNINGS AND CAUTIONS DO NOT OPERATE THE INSTRUMENT AROUND EXPLOSIVE GAS OR VAPOR AVOID WORKING ALONE BEFORE USE, INSPECT THE INSTRUMENT, LEADS AND ACCESSORIES FOR MECHANICAL DAMAGE, AND REPLACE WHEN DAMAGED PAY SPECIAL ATTENTION TO THE INSULATION SURROUNDING THE CONNECTORS AND PLUGS REMOVE ALL ACCESSORIES THAT ARE NOT IN USE MAKE SURE THE INSTRUMENT IS PROPERLY GROUNDED TO A
SEE ALSO: What You'll Need Unpacking Components & Accessories G4500 BLACKBOX Unit G3500 BLACKBOX Unit 15 ELSPEC G4500 & G3500 Portable Power Quality Analyzer USER & INSTALLATION GUIDE
What You'll Need Familiarize yourself with the G4500 & G3500 BLACKBOX Unit, Components & Accessories. In addition, ensure that you follow the outlined Safety Precautions.
Unpacking Components & Accessories The Portable BLACKBOX is shipped from Elspec's factory in a sealed case to protect it from damage during transportation. The small parts are shipped in a sealed bag with the unit.
QUANTITY ILLUSTRATION DESCRIPTION & PART NUMBER Carrying Trolley Case (For Mobility) 1 5 AC VOLTAGE TEST LEADS & CLIPS: 1 Black Voltage Cord with Crocodile Clip + Fuse (3M) EAH-4303-5100 Red Voltage Cord with Crocodile Clip + Fuse (3M) EAH-4303-5200 Blue Voltage Cord with Crocodile Clip + Fuse(3M) EAH-4303-5300 Yellow Voltage Cord with Crocodile Clip + Fuse(3M) EAH-4303-5400 Green Voltage Cord with Crocodile Clip(3M) EAH4303-9500 2 DC VOLTAGE TEST LEADS & CLIPS2: 1 Black Vo
QUANTITY ILLUSTRATION DESCRIPTION & PART NUMBER 48VDC Terminal Block Connector (RoHS Compliant): 1 ENT-1002-0190 Temperature Sensor Terminal PT100 Type (RoHS Compliant) 1 RS485/422 Communication Connector (RoHS Compliant) Terminal Block ENT-1004-0190 Multi IO Terminal Block Connector (RoHS Compliant) 1 ENT-2008-0190 Relay Terminal Block Connector (RoHS Compliant) 1 ENT-1003-0190 LAN Communication Cord Length: 2M 1 TOE-0010-0013 Relay Terminal Block Connector (RoHS Complian
Orders for optional accessories will be delivered as well in a sealed casing. Unpack these parts from their sealed bags: OPTIONAL ACCESSORIES QUANTITY ILLUSTRATION DESCRIPTION & PART NUMBER GPS (Global Position System) (For Mobile Time Synchronization) As Ordered SOA-0232-0400 Multi-Frequency 3.
QUANTITY ILLUSTRATION DESCRIPTION & PART NUMBER Custom Clamp 3-Flexible Current Probes SOA-3000-0270 As Ordered Current Range 30A / 300A / 3000A AC RMS Operating Temperature -20ºC to + 65ºC Probe Cable Length 610mm (24”) Probe Cable Diameter 194mm (7.5”) DC Current Custom Clamp SOA-0270-1400 As Ordered Current Measurement 1,500A DC / 1,000A AC Output Signal 1m V/A, 10m V/A Operating Temperature - 20°C to + 60°C Cable Length 1.
QUANTITY ILLUSTRATION DESCRIPTION & PART NUMBER 300 A Flexible Current Clamp SOA-9091-3000 As Ordered Measurement Range 9A ÷ 1050A Output Signal AC: 46mV/1KA Operating Temperature -20ºC to + 60ºC Cable Length 2m 3000 A Flexible Current Clamp SOA-9045-3001 As Ordered Measurement Range 10Hz ÷ 20kHz Output Signal AC: 46mV/1KA Operating Temperature -20ºC to + 60ºC Cable Length 2m Adaptor - Elspec Clamps to BNC (160cm) As Ordered SOA-0270-0000 Adaptor - Elspec Clamps to Fixed Banana (60cm) As Or
The G4500 BLACKBOX Portable PQ Analyzer The innovative design of the G4500 BLACKBOX has been uniquely adapted for PQ Analysis at any location. It continuously records all waveform data at a sampling rate for Voltage 1,024 samples per cycle & Current 256 samples per cycle. With an onboard memory of 32GB you can capture everything for more than a year depending on the selected resolution & the individual network condition.
Physical layout of the controls & indicators of the G4500's Rear Panel: INDICATOR / CONTROL DETAILED USAGE REFERENCE FRONT PANEL Wi-Fi Activity & Antenna Wireless Single PC Connection Auxiliary Power Supply Unit Powering Digital Inputs IO Ports Serial Ports Establish 1ST Time Connection USB Network Communication Port Establish 1ST Time Connection Battery Indicator Battery Replacements Power Indicator Unit Powering Main Power Supply On/Off Switch Unit Powering LAN Ports Establish 1ST Time
REAR PANEL Voltage Clamp Inputs Connect Voltage Probes Current Clamp Inputs Connect Current Clamps DC Current Input Connect Current Clamp DC Voltage Inputs Connect Voltage Probes Main Power On/Off Switch Unit Powering Main Power Inlet Socket Unit Powering SEE ALSO: Safety Precautions What You'll Need Unpacking Components & Accessories G3500 BLACKBOX Unit 25 ELSPEC G4500 & G3500 Portable Power Quality Analyzer USER & INSTALLATION GUIDE
The G3500 BLACKBOX Portable PQ Analyzer The innovative design of the G3500 BLACKBOX has been uniquely adapted for PQ Analysis at any location. It continuously records all waveform data at a sampling rate for Voltage 512 samples per cycle & Current 512 samples per cycle. With an onboard memory of 256MB you can capture everything for more than a year depending on the selected resolution & the individual network condition.
INDICATOR / CONTROL DETAILED USAGE REFERENCE FRONT PANEL Auxiliary Power Supply Unit Powering Digital Input IO Ports Serial Ports Establish 1ST Time Connection Battery Supply Battery Replacements Power Indicator Unit Powering LAN Ethernet Port Establish 1ST Time Connection Reset Button Instrument Settings Relay Port IO Ports REAR PANEL Voltage Clamp Inputs Connect Voltage Probes Current Clamp Inputs Connect Current Clamps Main Power On/Off Switch Unit Powering Main Power Inlet Socket
Installation This section contains the installation & setup procedure for the Portable BLACKBOX that is quick & simple to follow.
Unit Powering You may either power up either G4500 / G3500 Portable BLACKBOX by using the main AC Power Supply / the Auxiliary Power Supply / Battery Power Supply: CONNECT BY USING THE AC POWER SUPPLY: WARNING 85-260V AC ± 10%, 50/60Hz 2A/250V Fuse Holder OR Use only suitable fuse replacement! 120-370V DC Make sure the Instrument is properly grounded through the power cord to protective earth ground 35-55V DC Watt Maximum On the Rear Panel connect the female end of the Power Cable to the
CONNECT BY USING THE AUXILIARY POWER SUPPLY: WARNING 48V DC (35- 55V) 35 Watt Maximum On the Front Panel connect the female end of the Auxiliary Cable to the Auxiliary Port of the unit to the corresponding +/- connection: On the Front Panel turn on the Main Power Supply Switch to the ON position: No replaceable fuse protection! Do not allow significant overvoltage! The 48VDC power supply should be isolated from the mains by double or reinforced insulation Verify that the unit is runnin
POWER THE UNIT BY USING THE BATTERY SUPPLY: The BLACKBOX Portable contains an internal, uninterrupted power supply module providing a short period of self-powered measurements sessions &/or power supply interruptions ridethrough. The Internal UPS system contains a lithium battery for a up to 2 hours of fullyfunctioning operation & a super capacitors module allowing an additional 25 seconds of short interruptions ride-through even in the case of the main battery being fully discharged.
G4500 & G3500 Unit Wiring An essential part of the Wiring Procedure is the Power Configuration, which is configured in the Web Interface. Prior to proceeding with Plugging in & Playing your Voltage & Current Probes, familiarize yourself with the types of Power Topology the BLACKBOX Portable supports & Grounding of the unit. BLACKBOX PORTABLE POWER TOPOLOGY SUPPORTS The BLACKBOX is designed to serve in virtually any power topology configuration.
2PHASE TR [SINGLE SPLIT PHASE]: DELTA 3 WIRES [THREE WIRE DELTA]: 33 ELSPEC G4500 & G3500 Portable Power Quality Analyzer USER & INSTALLATION GUIDE
DELTA 3 WIRES [GROUNDED DELTA]: WYE 4 WIRES [FOUR WIRE WYE]: 34 ELSPEC G4500 & G3500 Portable Power Quality Analyzer USER & INSTALLATION GUIDE
WYE 4 WIRES [THREE WIRE WYE]: DELTA 3 WIRES [DELTA HIGH LEG]: 35 ELSPEC G4500 & G3500 Portable Power Quality Analyzer USER & INSTALLATION GUIDE
DELTA 3 WIRES [DELTA OPEN LEG]: SEE ALSO: 36 About Quick Installation Unit Powering Plug and Play Voltage & Current Probes Grounding Establish 1st Time Connection Unit Access About Quick Configuration Verify Measurement Readings Enable PQZIP Recording ELSPEC G4500 & G3500 Portable Power Quality Analyzer USER & INSTALLATION GUIDE
Grounding The Portable BLACKBOX contains two independent ground systems, one for measurements & one for safety. Internally the ground systems are isolated in order to avoid ground loops. Externally they may be safely connected to the same or different ground systems. Point 1 - Measurement Ground: The reference point for measured electrical system, Point 2 - Safety Ground: The reference for the line cord ground.
Plug & Play - Voltage & Current Probes The Portable BLACKBOX houses 5 x AC Voltage, 4 x AC Current & 1 x AC/DC Current Sockets. In addition the G4500 houses 2 x VDC Sockets. It is a simple matter of plugging in the Voltage & Current Probes into the device & it will be automatically recognized. The BLACKBOX is designed to serve in virtually any power topology configuration, see Circuit Topologies in order to interface your device with your circuit topology.
The LED light will illuminate confirming a solid connection & the Voltage Levels are above 10% of the nominal value: SPECIFICATION G4500 G3500 Maximum Voltage Input 1KV 1KV Nominal Voltage Range 110 to 690V 110 to 690V Maximum Peak Measurement Voltage 8KV 8KV Input Impedance 3MΩ 3MΩ Bandwidth 25kHz 12.5kHz Nominal Frequency 42.5Hz to 69Hz 42.5Hz to 69Hz PLUG IN THE CURRENT PROBES: You may use any clamp (either Elspec / Custom clamps). The clamps convert current to low voltage.
The LED light will illuminate confirming a solid connection: SPECIFICATION G4500 G3500 Number of Inputs 4 (3 Phases & Neutral) + DC/Ground 4 (3 Phases & Neutral) Maximum Peak Measurement I1 to I4: 10 VPk I5: 3 VPk From Clamp I1 to I4: 10 VPk From Clamp Type Clamp On Current Transformer With mV Output Clamp On Current Transformer With mV Output Range I1 to I4: 0 to 10 VPk I5: 0 to 3 VPk From Clamp I1 to I4: 0 to 10 VPk From Clamp Burden 0.05VA (Typical) @ 5 IRMS 0.
SPECIFICATION Maximum Voltage Input 1KV Galvanic Insulation from Main AC / DC Channels 3KV Recording Resolution 200 μs Go to the next step - Establishing a 1st Time Connection SEE ALSO: About Quick Installation Unit Powering About Portable Wiring Grounding Establish 1st Time Connection Unit Access About Quick Configuration Verify Measurement Readings Enable PQZIP Recording
Establish 1st Time Connection A quick & simple connection can be established to your Network or G4150 or your local PC by using the Portable BLACKBOX's fast Ethernet ports (10/100 MB) / Wireless Link.
The S/N is located on the G4500's name plate: The Wi-Fi Activity Indicator will confirm connection (Flashing / Solid Blue): G3500 LAN/LCD CONNECTION 43 After you have switched on your G3500 Portable PQ Analyzer, connect the LAN Communication Cord to the port marked LAN/LCD on the units' Front Panel: ELSPEC G4500 & G3500 Portable Power Quality Analyzer USER & INSTALLATION GUIDE
The green link-LED of the LAN1 connector begins to flash as Windows begins communicating with the unit Wait for about 2 minutes as the Windows operating system reverts to the default "No Server" IP configuration When this is completed, the "Local Area Connection Status" icon in the "Quick Start" tray will change to "Limited or no connectivity": SEE ALSO: 44 About Quick Installation Unit Powering About Portable Wiring Grounding Plug and Play Voltage & Current Probes Unit
G4500 / G3500 Unit Access Once you have Connected the Device for the 1st Time, you may access your Portable BLACKBOX Unit by simply clicking the WEB Hyperlink button in your Elspec's Search Utility. Alternatively you can simply access the device directly via the Internet Explorer by inserting the Device's IP address directly (address is also indicated in Elspec's Search Utility).
A scan procedure is initiated; the Elspec Search utility appears as a grid displaying all BLACKBOX devices found on the intranet network: ACCESS INSTRUMENT VIA THE WEB HYPERLINK (RECOMMENDED): Select the Web link for your device, Elspec's Web Interface will now open: In order to view the different languages in the Web Interface, you will need to upload the language feature from Elspec's Website when installing your new Firmware.
The Password field defines user level/privileges. The user levels are Viewer / Administrator (See Security Settings). The default password including privileges for each level are: Viewer is 123 (Read only, can choose interface language only, no operations related changes are allowed) Administrator is 12345 (Administration, setup & full control) NOTE NOTE NOTE The Website is optimized to work with Internet Explorer 7, 8 or 9 in “Compatibility View”.
SEE ALSO: 48 About Quick Installation Unit Powering About Portable Wiring Plug and Play Voltage & Current Probes Grounding Establish 1st Time Connection About Quick Configuration Verify Measurement Readings Enable PQZIP Recording ELSPEC G4500 & G3500 Portable Power Quality Analyzer USER & INSTALLATION GUIDE
About Quick Unit Configuration This section focuses only on the major configurations needed for initial installation of your Portable BLACKBOX device. Configurations are done via Elspec's Web Interface. For a more detailed & comprehensive procedure see Instrument Settings.
Quick Unit Configuration After you have Plugged in your Device, you will need to configure the unit itself. Access your Portable Device via Elspec's Web Interface as the Administrator Device Info Tab: 50 under Configuration log on Device Setup select the In the G4 Unit Configuration Section complete: Site Name: Enables the user to define a description of the site where the device is installed.
To review your changes select Go to the next step Configuring Voltage & Frequency NOTE NOTE NOTE If you are not logged on as the Administrator, you will not be able to change any of these settings & you will receive the following error message in your attempt to do so: Once you have signed on at the Administrator ensure that you select to actually affect your changes.
Voltage & Frequency Configurations As mentioned previously, after you have Plugged in the Voltage Probes it will be automatically recognized. Therefore, only minor configuration adjustments will need to be made in the Voltage & Frequency Configuration Window.
For MV/HV Networks (Voltage Measurements by PT's) set the correct Primary & Secondary Ratio (with /) – according to the PT Manufacturer's Specifications & not just the Ratio: Define the Nominal Values for Frequency (F) and Voltages (V) (with / ): The ratio for LV Networks (<1kV) is based on the same concept & specifications: Set the Primary & Secondary Ratio (with /) –(according to the PT Manufacturer's Specifications & not just the Ratio): To apply your changes select your changes Go to
Once you have signed on at the Administrator ensure that you select to actually affect your changes.
Currents As mentioned previously, after you have Plugged in your Current Probes it will be automatically recognized. Therefore, only minor configuration adjustments will need to be made in the Current Configuration Window.
To apply your changes select changes to review your NOTE NOTE NOTE If you are not logged on as the Administrator, you will not be able to change any of these settings & you will receive the following error message in your attempt to do so: Once you have signed on at the Administrator ensure that you select to actually affect your changes.
About Verifying Measurement Readings The final step after you have Configured your Device, is to verify the voltage & current measurements of your Portable BLACKBOX. This verification step covers only a partial section of the BLACKBOX's Full PQ Monitoring Capabilities.
Access the Measurement Summary The Measurement Summary summarizes all your measurement readings.
SEE ALSO: About Measurement Readings Verify Voltage & Current Verify Power 59 ELSPEC G4500 & G3500 Portable Power Quality Analyzer USER & INSTALLATION GUIDE
Verify Voltage & Current Readings This page displays specific values as per the parameters configured for Voltage & Current for your G4500/G3500 Unit. For a full description on all the definitions & subsequent parameter calculations see Voltage & Current.
Go to the next step - Verifying your Power in order to verify that the Active Power readings are based on your Current Configurations SEE ALSO: About Measurement Readings Access Measurement Summary Verify Power 61 ELSPEC G4500 & G3500 Portable Power Quality Analyzer USER & INSTALLATION GUIDE
Verify Power Readings Although Power Configurations is comprehensively dealt with in the Power Section, this section is necessary to verify that all the Active Power readings reflect Positive Values. Corrections can be made by toggling the polarity in the Current Configurations. For a full description on all the configurations, definitions & subsequent parameter calculations see Power.
SEE ALSO: About Measurement Readings Access Measurement Summary Verify Voltage & Current 63 ELSPEC G4500 & G3500 Portable Power Quality Analyzer USER & INSTALLATION GUIDE
Enabling PQZIP Recording In order to record actual data for further analysis by PQSCADA & Investigator, you must first enable the PQZIP Recording. HOW TO ENABLE PQZIP RECORDING Access your Portable BLACKBOX Unit via the Web Interface Configuration 64 Open PQZIP Recording In the State drop-down selection select Enable: To apply your changes select The following warning may appear if some parameter readings are inconsistent with the configuration.
NOTE NOTE NOTE If you are not logged on as the Administrator, you will not be able to change any of these settings & you will receive the following error message in your attempt to do so: Once you have signed on at the Administrator ensure that you select to actually affect your changes.
Battery Replacement The BLACKBOX Portable is equipped with an internal lithium battery that will allow you to operate the BLACKBOX for up to 2 hours without having to connect to either an AC/DC external power source. The battery requires no maintenance whatsoever & is designed for a long-life service. However, should the battery's performance decrease significantly, it will need to be replaced with an original component that can be either ordered directly from Elspec or, from your local Elspec Agent.
Remove The Malfunctioned Battery Ensure you Have all You Need & have taken the necessary Safety Precautions.
Replace The New Battery After you have Removed the Malfunctioned Battery, you can now proceed to replace it: Place the New Battery in the Battery Housing: Reconnect the Plug Connector from the battery to the Terminal Inside the Device. Ensure that the wires are properly tucked into the housing: Replace the Front Panel & re-secure the screws. Replace the Rubber Cover. Re-connect all the Power & Communication Cables.
Specifications This section includes common specifications for the Portable BLACKBOX: INPUT CHARACTERISTICS: VOLTAGE INPUTS G4500 G3500 Number of Inputs AC: 4 (3 Phases & Neutral) AC: 4 (3 Phases & Neutral) DC: 1 Maximum Input Voltage (VRMS) 1KV 1KV Nominal Voltage Range (VRMS) 110 to 690V 110 to 690V Maximum Peak Measurement Voltage (VPk) 8KV 8KV Input Impedance 3MΩ 3MΩ Bandwidth 25kHz 12.5kHz Nominal Frequency 42.5 to 69Hz 42.
MEASUREMENT RANGE, RESOLUTION, ACCURACY: VOLT/AMPS/HERTZ MEASUREMENT RANGE RESOLUTION ACCURACY 0 to 900V 0.01V ±0.1% of Nominal Voltage1 With SOA-9045-3001 90A to 15kA 0.1mA ±0.5% ±0.5A of Nominal Current2 With SOA-9091-3000 9 to 1.5kA 0.1mA ±0.8% ±0.1Aof Nominal Current2 With SOA-0010-0500 0.02 to 6A 0.1mA ±0.15% ±0.5mAof Nominal Current2 VPk 8KV 10mV ±0.1% from Reading Voltage Crest Factor 1< 0.01 Better than 0.5% Current Crest Factor 1< 0.01 Better than 0.
MEASUREMENT RANGE, RESOLUTION, ACCURACY: POWER & ENERGY MEASUREMENT RANGE RESOLUTION ACCURACY Active Power Depends on Clamp & PT Configuration 10mW ±0.2%1 Reactive Power Depends on Clamp & PT Configuration 10mVAR ±2%1 Apparent Power Depends on Clamp & PT Configuration 10mVA ±0.2%1 Active Energy Depends on Clamp & PT Configuration 10mWh ±0.2%1 Reactive Energy Depends on Clamp & PT Configuration 10mVArh Apparent Energy Depends on Clamp & PT Configuration 10mVAh ±0.
GENERAL SPECIFICATIONS: STORAGE CAPACITY G4500 G3500 Internal Memory 32GB 256MB STORAGE CAPACITY Real Time Clock ± 1 Second per 24 Hours Time Synchronization Optional GPS/SNTP/IRIGB/DCF-77 time sync module provides time uncertainty better than 100μs. When synchronization becomes unavailable, Time Tolerance is 1 second per day.
GENERAL SPECIFICATIONS: RS485/422 CONNECTION Baud Rate Configurable: 1200 / 2400 / 4800 / 9600 / 14400 / 19200 / 38400 57600 / 115200 Communication Protocols PPP & TTY Duplex Full Maximum Cable Length 15.2m (50’) RS232 CONNECTION (COM Compatible Interface) Default Configuration Baud rate: 19200, Data Bits: 8 , Parity: None, Stop Bits: 1 Communication Protocols GPS Duplex Full Maximum Cable Length 15.
PQZIP RECORDING: METHOD 1 PQZIP compression technology which enables continuous gap-less recording of all electrical parameters-related data for a significant time duration without the need of event thresholds of any kind. Events, Flicker and Energy are noncompressed parameters. WAVEFORM G4500 G3500 Voltage Sampling per Cycle 1024/512 512 Current Sampling per Cycle 256/512 512 Recording Time 1 + Year Continuous Recording at a Fixed Ratio Mode of 2.
IO PORTS: DIGITAL INPUTS Channels 4 Sampling 800 Hz @ 50Hz (16 Samples per Cycle) 960 Hz @ 60Hz (16 Samples per Cycle) Range DC: 0 – 220V Pulse Type 0->1->0, 1->0->1, KYZ Isolation Connector 125V RELAY OUTPUT Channels 1 x Change Over Contact Configuration 1 CO (SPDT – Single Pole Double Throw) Maximum Switching Voltage AC: 277V Maximum Current AC: 5A/250V; 10A/110V DC: 5A/30V Maximum Peak Current 15A Rated Current 6A Operating Time 4ms Release Time 6ms Maximum Reaction time 10ms
Physical Specifications Portable BLACKBOX & Dimensions of the PHYSICAL SPECIFICATIONS PHYSICAL Dimensions 314mm x 84mm x 269mm (12.36” x 3.3” x 10.59”) Weight 3.7Kg (8.15Lb) ENVIRONMENTAL Design Rugged, Shock Proof with Integrated Protective Holster Drip & Dust Proof IP20 according to IEC60529 when used in tilt standard position Shock & Vibration Shock 30g, Vibration: 3g Sinusoid, Random 0.
DIMENSIONAL VIEW G4500: 77 ELSPEC G4500 & G3500 Portable Power Quality Analyzer USER & INSTALLATION GUIDE
DIMENSIONAL VIEW G3500: SEE ALSO: 78 G4500 G3500 Specifications ELSPEC G4500 & G3500 Portable Power Quality Analyzer USER & INSTALLATION GUIDE