User Manual

18
Press to exit Walk Test and return to the top
level Test Mode menu.
RF ENVIRONMENT TEST
Scroll through the top level Test Mode menu until RF
Environment is displayed.
If the ambient environment is full of radio frequency, an
indication of
ENVIRON . . POORwill be shown
on the LCD screen.
DIGITAL DIALER TEST
Scroll through the top level Test Mode menu until
‘DIGITAL DIAL TEST’ is displayed and press .
In order to test the digital dialer properly, the
prerequisite is to set the telephone number, unit ID
number and to turn on ‘4-2-1 Monitor Center’ in the
programming mode. If the telephone number is o.k,
‘TEST….PASS’ will be shown. If ‘TEST….FAIL is
shown with ‘LINE STATUS’ LED flashing, please check
the telephone line is well connected and retry the test
again.
When testing is in progress, simply press to
stop testing.
VOICE DIALER TEST
Scroll through the top level Test Mode menu until
‘VOICE DIAL TEST’ is displayed and press .
In order to test the voice dialer properly, the
prerequisite is to set the telephone number, record the
message for main and intruder, and to turn on voice
dial in the programming mode. If ‘LINE STATUS’ LED
is flashing, please check the telephone line is well
connected and retry the test again.
When testing is in progress, simply press to
stop testing.
WIREFREE SIREN SERVICE ON/OFF
Scroll through the top level Test Mode menu until
‘Wirefree Siren Service ON/OFF’ is displayed and
press .
This offers the flexibility of removing or changi ng siren’s
battery. Wait for 10 seconds until ON/OFF duration
has elapsed, then go ahead with fixing the siren as
desired.
ALARM TEST
Scroll through the top level Test Mode menu until
‘ALARM TEST’ is displayed and press .
Scroll though the menu until the required alarm
displayed and press to operate the selected
alarm for 5s.
Select ‘Wirefree Siren Test’ to operate the External
Solar Siren.
Select ‘Hardwire Siren Test’ to operate the Smart
Home Box Siren and external hardwired Siren (if
connected).
Select ‘Relay Test’ to operate the External hardwired
(N.O./N.C.) relay contacts.
Press to exit Alarm Test and return to the top
level Test Mode menu.
DEFAULT SETTINGS
User Setup
Admin: 1234
Password
User 1~7:
Not Programmed
Name Admin. User 1~7
Tel/SMS Remote Admin: ON
User 1~7: OFF
Latchkey Rep ort OFF
Record User Message Not Programmed
Replay User Message Not Program m ed
Remoter Not Programmed
Home Box Setup
Alarm T ime 180s
Internal Siren ON
Wire Siren ON External
Siren
Wireless Siren ON