Read and Retain for Future Reference S2900 Radio Module Integrator Installation Manual Version 1.
Elpro Technologies E2-450 Radio Transceiver Module Instruction Manual ATTENTION! Incorrect termination of the supply wires may cause internal damage. Before turning the power on double-check ALL connections by referring to this User Manual. CAUTION To comply with FCC RF Exposure requirements in section 1.1310 of the FCC Rules, antennas used with this device must be installed to provide a separation distance of at least 90 cm from all persons to satisfy RF exposure compliance.
Elpro Technologies E2-450 Radio Module Instruction Manual Safety Notices: Exposure to RF energy is an important safety consideration. The FCC has adopted a safety standard for human exposure to radio frequency electromagnetic energy emitted by FCC regulated equipment as a result of its actions in Docket 93-62 and OET Bulletin 65 Edition 97-01. User Notification THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES.
Elpro Technologies E2-450 Radio Transceiver Module Instruction Manual CONTENTS CHAPTER 1 - INTRODUCTION ......................................5 CHAPTER 2 - Module Description ...................................5 CHAPTER 3 - Main Host Interface ..................................5 Alternate Host Interface ................................................... 6 Production Interfaces ....................................................... 6 CHAPTER 4 - OPERATION.............................................
Elpro Technologies E2-450 Radio Module Instruction Manual CHAPTER 1 - INTRODUCTION The S2900 is a radio modem module that will be used as a base radio for a number of Elpro wireless products in the future. It will be primarily used to act as a wireless network adapter for transfer of 802.11 data frames over lower speed wireless links. The S2900 consists of a host microcontroller, an RF transceiver section, and a power supply section.
Elpro Technologies E2-450 Radio Module Instruction Manual • SELECT • MISO Synchronous serial data from radio to controller • MOSI Synchronous serial data from controller to radio • SCK Serial clock for data transfer between controller and radio • CMD_ENA Enable Commands after startup is complete. • CMD_ACK Indicate Radio is ready to receive commands (Rx disabled).
Elpro Technologies E2-450 Radio Module Instruction Manual 0xF0 Select Hop Set S1 (Default) 0xF1 Select Hop Set S2 0xF2 Select Hop Set S3 0xF3 Select Hop Set S4 0xF4 Select Hop Set S5 0xF5 Select Hop Set S6 0xF6 Select Hop Set S7 0xF7 Select Hop Set S8 0xF8 Set lead-in to 350 mSec (To wake sleeping slave) 0xF9 Set lead-in to 30 mSec (Default) 0xFA Set lead-in to 3 mSec (controlled frequency operation) 0xEF Start Transmission with next hopping sequence frequency 0xEE Request Signal St
Elpro Technologies E2-450 Radio Module Instruction Manual SELECT MOSI Start Byte 0 Byte 1 BYTE_READY Radio TX data Lead-in SYNC Byte 0 Byte 1 End of Frame Data from Radio to Controller Data from the radio to the controller always consists of received radio data. Data transfer is initiated by the radio raising the BYTE_READY signal. The Controller then lowers the SELECT line, and transfers the data from the radio. The radio raises the BYTE_READY signal as soon as a radio lead-in is detected.
Elpro Technologies E2-450 Radio Module Instruction Manual Frame reception – valid data frame. RX Data Lead-in SYNC Byte 0 Byte 1 End of Frame RSSI Byte 0 Byte 1 B_RDY SELECT MISO Lead-in Found End Of Frame Timer (Controller) Controller Detects End of Frame If the radio loses lead-in lock before the sync word is received, then an RSSI value of 0xFE is transferred to indicate no more data to follow. The Lead-in Found code is 0xFF.
Elpro Technologies E2-450 Radio Module Instruction Manual current channel then raises the BYTE_READY line to indicate to the controller that the RSSI data is ready. The controller then transfers the RSSI data from the radio with a second SPI transfer. Country Code Request If the Host Controller supports operation in multiple countries, the country code may be requested from the radio. The host controller sends the code 0xED (Request Country Code).
Elpro Technologies E2-450 Radio Module Instruction Manual START Controller Sends “Receive” Command Radio Lowers CMD_ACK Radio Raises CMD_ACK Receive Comman d Radio Raises CMD_ACK Controller Lowers CMD_REQ Rev Version 1.0 www.cooperbussmann.
Elpro Technologies E2-450 Radio Module Instruction Manual CHAPTER 5 - Locale The S2900 radio is designed to operate in frequency bands 902 MHz to 928 MHz. These bands are fully supported for North America.
Elpro Technologies E2-450 Radio Module Instruction Manual CHAPTER 7 - Protective Earthing Point There are five mounting screw points around the cage, 4 of which are connected to the ground plane of the module. These should be screwed on with metallic screws to the metallic casing or ground points on the host system.
Elpro Technologies E2-450 Radio Module Instruction Manual CHAPTER 9 - LABELLING Sample Label 14 1.0 www.cooperbussmann.