User's Manual
Chapter Five Specifications
Page 23 © February 2005
Enable Tick to enable serial gateway access.
Data Rate Select serial data rate
Data-Parity-Stop bits Data bit – Parity – Stop bits
Flow Control Enable hardware flow control
Character Timeout Packets are transmitted once a ?? bytes have reached or there have
been no characters received on the serial port for the time nominated
in Character Timeout.
Listen Port The port address on which the 905U-E is to listen for a socket.
Send IP Address The IP address to which the 905U-E is to attempt to connect the
serial port to.
Send Port The port address to which the 905U-E is to attempt to connect the
serial port to.
Apply Changes Update settings in RAM.
Apply Changes and Save Update settings in RAM and save to non-volatile memory.
Module Information Webpage Fields
This configuration page is primarily for information purposes. With the exception of the
password, the information entered here is displayed on the root webpage of the 905U-E.
Password Configuration password. When changing the password on this
screen, it will be sent unencrypted over any wired network. If
encryption is enabled on the 905U-E, any radio communications are
encrypted, and therefore hidden from radio eavesdroppers. Caution
must only be taken if there are potential eavedroppers on the wired
network.
Device Name A text field for a nickname of the particular 905U-E.
Owner A text field for owner name.
Contact A text field for owner phone number, email address etc.
Description A text field used for a description of the purpose of the unit.
Location A text field used to describe the location of the 905U-E.