rate to be X Hz, then the analog value will be 100% at X Hz increasing, and 0% value at X Hz
decreasing.
4.8 Number of Transmissions
This parameter allows you to
select the number of
transmissions for each
message. For example, if 3
is selected, then each
message will be transmitted
three times. The time
between each transmission
will be a random time
between 0.5 and 4 seconds.
The valid choices for this
option are 1 - 5.
4.9 Programming Configurations to Modules
To program a module :
Connect the cable from the PC’s serial port to the 905K serial port (see 3.5.4 for cable
connections)
From the Utilities menu, select “Serial Port Setup
Select the appropriate serial port (COM1 - COM4)
Select the unit to be configured from the left-hand menu
Click on the “Program Unit” button.
You will be asked to confirm, if the module already has a different system or unit address.
Each module will need to be programmed individually.