User manual
Chapter 4 Configuration
MAN_905G_1.16 Page 122
I/O Data Input Mapping Object, Class A0h
This object is setup dynamically via fieldbus read mappings through configuration software.
This data is also available as vendor specific Instance Attributes (64h to 69h) in the
Assembly Object.
Class Attributes:
ID# Name Service Description Semantics
Def,
Min,
Max
Type
01h Revision Get_attribute_all Object
Revision
The revision
attribute containing
the revision of the
object
1,
1,
1
UINT
Instance Attributes, Instance 01h:
ID# Name Service Description Type
01h Data Get_attribute_single The data produced is configured from fieldbus
write mappings to I/O Input Instance 1.
Array of
USINT
…… … … …
06h Data Get_attribute_single The data produced is configured from fieldbus
write mappings to I/O Input Instance 6.
Array of
USINT
I/O Data Output Mapping Object, Class A1h
This object is setup dynamically via fieldbus write mappings through configuration software.
This data is also available as vendor specific Instance Attributes (96h to 9Bh) in the
Assembly Object.
Class Attributes:
ID# Name Service Description Semantics
Def,
Min,
Max
Type
01h Revision Get_attribute_all Object
Revision
The revision
attribute containing
the revision of the
object
1,
1,
1
UINT
Instance Attributes, Instance 01h:
ID# Name Service Description Type
01h Data Get_attribute_single
Set_attribute_single
The data produced is configured from fieldbus
write mappings to I/O Input Instance 1.
Array of
USINT
…… … … …
06h Data Get_attribute_single
Set_attribute_single
The data produced is configured from fieldbus
write mappings to I/O Input Instance 6.
Array of
USINT