User manual

Chapter 6 Diagnostics
Elpro_man_105g_1.18.doc Page 134
Chapter 5 Specifications
General
EMC approval EN55022, EN 50082-1,
ETS 300 683, AS 3548
IEC60950
Radio standards
MPT 1329 UK
EN-300-220
AS 4268.2 AUST
RFS29 NZ
EN 300 113, FCC Part 90
458 MHz, 500 mW EIRP
405 - 490 MHz, 10 - 500 mW
869 MHz, 500mW
472 MHz, 100 mW EIRP
458 MHz, 500 mW EIRP
380 – 520 MHz, 0.5 – 5W
Housing 130 x 185 x 60mm
DIN rail mount
Powder-coated, extruded aluminium
Terminal blocks Removable Suitable for 2.5 mm
2
conductors
LED indication Power supply/OK, Active
operation, digital I/O, Radio
RX and TX, Serial RX and
TX
Operating Temperature 105G-MD1
105G-other
-20 to 60 degC (400MHz 500mW)
-30 to 60 degC (400MHz 5W)
-40 to 60 degC (869MHz 500mW)
0 to 60 degC (all radios)
Humidity 0 – 99% RH non-condensing
Power Supply
Battery supply 11.3 - 15.0 VDC
AC supply 12 - 24 VAC, 50/60 Hz
Overvoltage protected
Battery required for 105U units with more
than 2W RF power
DC supply 9 - 30 VDC Overvoltage and reverse voltage protected
> 17VDC required for charging battery
Battery required for 105U units with more
than 2W RF power
Battery Charging circuit Included, suitable for
12Vsealed lead acid batteries
Regulated to max 1.5 amp charging current
Normal Current Drain at
12VDC
105G-MD1
105G-other
150 mA
270 mA
add 5mA per active I/O
Normal Current Drain at
24VDC
105G-MD1
105G-other
90 mA
170 mA
add 3mA per active I/O