Specifications
ELECTRICAL
Power Requirements 24 VDC nominal ± 30%; 200mA. (500mA at start-up)
Power Consumption
Approx 2W (power consumption is a function of address
(per DIP switch settings, where FF=max and 00=min)
Status Indications
Power On: Red LED pulses 5 times upon power on; then remains constant.
Invalid ID Code: Red LED pulses continuously; Buzzer beeps repetitively
Frequency Output & Format
LF: 125KHz; 3 byte messages (Preamble, Exciter ID and CRC)
RF (supervision): 433.9MHz; Elpas Tag Format (see tag documentation)
Output Bit Rate 2,000 bits per second
Output Power Adjustable, using on-board trim control potentiometer
Magnetic Field - Effective Range Up to up to 3m (10ft) radius
Device Interfaces
RJ11 (6P6C) connector to power source via EJB box;
RJ45 (8P8C) to slave (master-slave configuration)
LF Power Transmission Output Less than 60 dbµv at 30 meters (100 feet)
Supervisory RF Transmission
Rate
433.92 MHz RF transmission 2ms duration , 10 second intervals
LF Transmission Rate Continuous bursts of LF transmissions (each about 12ms in duration)
Supervision Management Using EIRIS software
Exciter ID code Set by on-board 8 position DIP-switch
GENERAL
Construction Polymer plastic
Dimensions 17cm x 4 cm (6.6 inches x 1.6 inches)
Weight 200 grams (0.45 lbs) approximate
Temperature & Humidity -10°to 70°C (14°to 159°F); 20% to 80% non-condensing
Fire Resistance Using optional fire proof cover (5-RDT09101)
Warranty One year limited warranty
FCC Compliance FCC Part 15.209 and 15.231e
FCC ID O4X5-RLE00125
Ordering Details
PART INFORMATION
5-RLE00125 LF Exciter
5-RLE00125-1 LF Exciter, Master
5-RLE00125-2 LF Exciter, Slave
5-RLE00125-W LF Exciter, WHT
5-RLE00125-1W LF Exciter, Master WHT
5-RLE00125-2W LF Exciter, Slave WHT
OPERATIONAL ACCESSORIES
5-RDT09103 RDR surface mount ring (5 units)
5-RDT09100 RDR1 mounting bracket (5units)
5-RDT09101 RDR1 fire proof cover (5units)
Standards Compliance
This device complies with Part 15 of the FCC Rules; and its operation is subject to
the following two conditions:
• This device may not cause harmful interference
• This device must accept any interference received, including interference
that may cause undesired operation.
For a Class B digital device or peripheral, the instructions furnished the user shall
include the following or similar statement, placed in a prominent location in the
text of the manual:
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Warning!
Changes or modifications to this equipment not expressly approved by the party
responsible for compliance (Visonic Technologies Ltd.) could void the user’s
authority to operate the equipment.