User's Manual

Elpas BTE Baby Tag User Guide
www.elpas.com
Page 3 of 4
V2/Nov 2013
Cleaning & Disinfection Procedures
Use an appropriate antibacterial disinfectant such as Dispatch
®
Hospital Cleaner Disinfectant with Bleach from Caltech Industries
(http://www.caltechind.com) to clean the Baby Tag.
Since ‘Cleaning Procedures’ may vary according to facility guidelines, thus the procedures given below are for illustrative purposes only:
Option 1 Using Dispatch Disinfectant Spray
1. Lightly wet a disposable towel with Dispatch spray
2. Do not saturate the towel
3. Wipe the outer surfaces of the sensor
4. Next wipe the sensor with a dry disposable towel
5. Allow the sensor to air dry
6. Return the clean sensor to inventory or usage
7. Dispose of used towels per facility policies
Option 2 Using Dispatch Disinfectant Towels
1. Open a new Dispatch pre-moistened towel
2. Wipe the outer surfaces of the sensor
3. Next wipe the sensor with a dry disposable towel
4. Allow the sensor to air dry
5. Return the clean sensor to inventory or usage
6. Dispose of used towels per facility policies
Product Specifications
Item
Description
RTLS Technologies
RF (433MHz) LF (125KHz)
RF Under LF
2 seconds; after 10 minutes returns to 10 seconds when in motion or 60 seconds when stationary
LF Sampling
Every 250ms
LF Timeout
Transmits burst of 3 non-LF messages when LF signal is not received for approximately 2 seconds
Supervision Events
Band Connected (B2 up), Low Battery
Band Disconnected /Tamper (B2 down)
LF (Entry/Exit), Matching, Pairing
3 RF transmissions (each transmission @ 2ms in duration), 250m-400ms apart (user configurable).
Power Source
Two Internal 3V Lithium batteries (Type: CR2025)
Average Battery Life
(Active 80% of the time)
2 years approximate
Red LED Status Indicator
Initial activation: Once for 3 seconds
Low Battery: Flashes once every 10 seconds
Entry/Exit LF zone, Band connected/disconnected: Flashes 3 times
Green LED Status Indicator
Positive mother/baby match result
Tag ID
Unique, factory-programmed ID
Construction
Nylon base & cap (IP-67)
Dimensions (H x W x D)
3.5 x 2.9 x 12cm (1.4 x 1.2 x 0.5 inches)
Weight
12 grams (0.4 ounces)
Storage Environment
Temp: -30°C to 70°C (-22°F to 159°F) Humidity: 100% non-condensing
Operating Temperature
Temp: -10°C to 70°C (14°F to 158°F) Humidity: 20% to 80% non-condensing
Management Software
Eiris V4.8 or higher (standard functionality)
Elpas V4.8 or higher ((local mother baby matching functionality)
Regulatory
IC, FCC & CE compliant
Warranty
1 year limited (excluding battery)
* Anti-tamper detection requires the usage of the Mounting Clip (Elpas P/N: 5-ETC09001) to attach the Tag to the asset to be protected
Product Accessories
Part Number
Description
TBD
Disposable Tamper Detection Band
Preliminary_V2