4. WIRING
The standard cable is color-coded. Use a cable with the same colors to avoid mistakes in connection. Connect each proximity reader to
the reader sections on the AXS-100 connector blocks.
4.1 Wiring the RDR-4
Each RDR-4 proximity reader is connected to the control unit via
a four-wire cable. See Figure 4 for color-coding.
FROM
RDR-4
READER
PWR
GND
TX
RX
RED
BLACK
GREEN
WHITE
AXS-100
TERMINAL
BLOCK
Figure 4. RDR 4 Color-Coding
4.2 Wiring the RDR-4B
The RDR-4B in conjunction with the AXS-100, facilitates a door ajar
annunciation next to each door. The RDR-4B connects to the AXS-
100 controller using the same four color wire as the RDR-4. The
two extra wires (brown and blue) should be connected to a local
12V / 50mA buzzer as follows:
Brown wire to buzzer +
Blue wire to buzzer -
The output current is limited to 50mA. See Figure 5 for color coding.
For activating the output of RDR-4B refer to the AXS-100 User
Guide section 5.2.3.
FROM
RDR-4B
READER
PWR
GND
TX
RX
RED
BLACK
GREEN
WHITE
AXS-100
TERMINAL
BLOCK
BROWN
BLUE
BUZZER
Figure 5. RDR-4B Color-Coding
4.3 Wiring the RDM-4
Each RDM-4 proximity reader is connected to the control unit via
a four-wire cable. See Figure 6 for color-coding.
TO RDM-4
READER
PWR
GND
TX
RX
RED
BLACK
GREEN
WHITE
AXS-100
TERMINAL
BLOCK
Figure 6. RDM-4 Color-Coding
5. REGULATORY
5.1 EU Declaration of Conformity
This equipment is in compliance with the essential requirements
and other relevant provisions of Directive 1999/5/EC.
5.2 Compliance FCC Compliance
These devices (FCC #:04X3-63040) complies with FCC Rules
Part 15.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, or that
may cause undesired operation.
Note: This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection against harmful interface in a residential installation.
This equipment generates; uses and can radiate radio frequency
energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio
communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined
by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications to this equipment not expressly approved
by the party responsible for compliance (Elpas Solutions Ltd.) could
void the user’s authority to operate the equipment.
5.3 Company Contact
Elpas, Inc.