Technical data

791342 Inst. Gas 2.0 8
4. Water drain A
Connect drain to the waste water system in accordance with the German standard
DIN 1986, section 1.
For UK the inlet supply shall be fed via fluid backflow prevention category three
arrangement such as a double check valve.
In accordance with DVGW instructions (DVGW = German technical scientific association
on gas and water) the appliance is intrinsically safe and can be connected directly to the
sewer without any further measures
Drain and air-vent pipe material must be steam temperature resistant.
Minimum diameter 50 mm, preferably not longer than 1 m, we recommend high temperature
resistant pipes type HT PA-I 1818 according to the German standard DIN 19560.
It is not permitted to taper the cross-section of the drain.
Slope of at least 5% is necessary.
Waste water temperature 80°C
To fill the siphon, give about 3 liters of clear water into the oven prior to any first start.
Fixed connection without trap
Fixed connection with trap
Drain fannel
The Eloma GmbH bears no liability for any damages caused by a not proper installation.