Technical data
791342 Inst. Gas 2.0 7
2.7 Heat emission into the area
Typ 6-11 10-11 20-11 12-21 20-21
Connected load kW 12.0 20.0 40.0 35.0 70.0
latent kJ/h 4.320 7.200 14.400 12.600 25.200
sensible kJ/h 3.672 6.120 12.240 10.710 21.420
3. Electrical connection EZ und Potential equalisation PE
Do not connect the unit to the mains if it has just been transported from a cold environment
into a warm room. Otherwise condensate may develop inside the combi steamer which may
cause damages.
Wait for about two hours until the unit has reached room temperature
Electrical connections must be carried out by an approved electrician in accordance
with VDE regulations and regulations of the local electricity supply companies
Pay attention to the data on the type plate for the electrical connections.
3.1 Standard connection
Typ 6-11 10-11 20-11 12-21 20-21
Connected load kW 12.0 20.0 40.0 35.0 70.0
Voltage 230 V, 31 N AC 50 Hz 400 V, 31 N AC 50 Hz
Fuse protection Amp. 1x16 1x16 1x16 3x16 3x16
The table models units are supplied with a connecting cable, length 2 m. In case this cable
has to be replaced for whatever reason, use a cable type H07RN-F according to German
VDE standards.
Next to the appliance an all-pole electric circuit breaker with a contact opening of at least 3mm
has to be provided for on site.
The appliance must be incorporated into the potential
equalisation system (ground).
You find the terminal under the indication plate.
In case a plug is mounted, the plug device must be accessible after setting-up.
Please note:
Î Do not fit a mains plug to the mains cable. Securely connect the mains cable to prevent
phase distortion.
Î Connect the phase to the brown cable (L), otherwise failures in the gas system will occur.
In such case the symbol “failure gas system“ would be displayed.
Î New start by pressing sensor key “Restart gas“ Combistemamer Genius Gas.
Î Use key
to acknowledge gas fault messages.
Combisteamer Multimax B Gas starts automatically.
Observe the sense of rotation of the fan when connecting to the mains.
Sense of rotation: In steam-mode the fan runs clockwise, check it from the cooking chamber.
Floor models rotation: In steam-mode the upper fan runs clockwise, the lower fan runs counter-clockwise,
check it from the cooking chamber.