Technical data
791342 Inst. Gas 2.0 4
− For maintenance and easy access to the unit for service operations use flexible water and
electric connections.
The appliance should be removable approximately 1 meter from its standard position.
1.4 Hints for setting up
− The floor underneath the appliance must be plane to ensure a smooth driving-in of the
trolley (roll-in pan-rack).
In case of a sloping floor underneath the unit, the trolley will be placed in an oblique position,
which might influence its proper functioning.
− Minor unevenness can be trued up using spacers at the wheel fastenings.
Major unevenness must be adjusted on site.
− Fix the appliance after adjusting the level and angle, so that the oven can’t shift anymore.
− There should be a minimum distance of 15 +/- 5 mm between the trolley and the top edge
of the oven cavity bottom.
− The trolley must never touch the door gasket and must be level with the appliance
1.5 Removal of protecting film
− Prior to starting the machine, the protective film must be removed from side, back and
cover surfaces. Use special cleaner to clean to perfection.
− Do not operate the oven with the adhesive film.
1.6 Noise level
− The emission value of the noise level is less than 70 dB (A)..
1.7 Exhaust air
− A built-in cooling function cools down water and steam of condensation, which runs down
the drain. It is therefore not necessary, however recommended, to install the appliance
under a ventilation hood.
− If such a hood is installed, its design and power rates should comply with the German VDI
regulation 2052.
− For Eloma combi-steamer a condensation hood is available as an option.
− Observe the installation manual “condensation hood” for proper installation of the hood
Spacer
Door gasket
15mm ± 5