791342 Inst. Gas 2.0 4
For maintenance and easy access to the unit for service operations use flexible water and
electric connections.
The appliance should be removable approximately 1 meter from its standard position.
1.4 Hints for setting up
The floor underneath the appliance must be plane to ensure a smooth driving-in of the
trolley (roll-in pan-rack).
In case of a sloping floor underneath the unit, the trolley will be placed in an oblique position,
which might influence its proper functioning.
Minor unevenness can be trued up using spacers at the wheel fastenings.
Major unevenness must be adjusted on site.
Fix the appliance after adjusting the level and angle, so that the oven can’t shift anymore.
There should be a minimum distance of 15 +/- 5 mm between the trolley and the top edge
of the oven cavity bottom.
The trolley must never touch the door gasket and must be level with the appliance
1.5 Removal of protecting film
Prior to starting the machine, the protective film must be removed from side, back and
cover surfaces. Use special cleaner to clean to perfection.
Do not operate the oven with the adhesive film.
1.6 Noise level
The emission value of the noise level is less than 70 dB (A)..
1.7 Exhaust air
A built-in cooling function cools down water and steam of condensation, which runs down
the drain. It is therefore not necessary, however recommended, to install the appliance
under a ventilation hood.
If such a hood is installed, its design and power rates should comply with the German VDI
regulation 2052.
For Eloma combi-steamer a condensation hood is available as an option.
Observe the installation manual “condensation hood” for proper installation of the hood
Spacer
Door gasket
15mm ± 5