Technical data
791342 Inst. Gas 2.0 14
Setting Service-Menue Combi-Steamer Multimax B Gas
Î Before adjusting the CO2 content, the right type of gas must be selected in the service menu.
To change the gas type, please set the following parameters:
Adjust time “3:45:00 AM”, and press the “Manual steaming” key for at least 2 seconds.
The time display briefly shows the software version, then Pr; the temperature display shows End.
You can now use the rotary selector switches to enter the different parameters according to the table below.
Time display
Rotary time selector
Temperature display
Rotary temperature selector
Core temperature display
Rotary core temperature selector
Level Pos Description Min Max Standard Unit
Service
Prg
Unit EP Parameter
3 3 Type of heating 0 3 0: Elektro; 1: GAS 2E/H,
2: GAS 2LL/L, 3: GAS 3B/P
3 13 Ignition load _cold 0 100 100 % %
3 14 Ignition load _warm 0 100 100 % %
3 15 Ignition time 0 100 10 sec 100msec
3 16 Operating load 0 100 75 % %
3 17 Operating load_lower chamber 0 100 78 % %
3 18 Ignition load_cold_ lower chamber 0 100 100 % %
3 19 Ignition load _warm_ lower chamber 0 100 100 % %
Save the changed operating parameters by pressing START/STOP key.
The steamer is now ready for operation; time display shows 0:00, and temperature display shows 99 °C.