Technical data
791342 Inst. Gas 2.0 13
8.2 Reference values – Settings
Appliance Gas Typet Venturi Operation
PWM [%]
Operation
PWM [%]
Ignition
load [%]
Ignition
load [%]
Ignition-
time [s]
upper
chamber
upper
chambe
r
CO2
[Vol%]
Remarks
6-11 Natural gas E (H)
003
79 100 10
10,0
6-11 Natural gas LL (L)
003
100 100
9,4
6-11 Liqiud gas
(Butan /Propan)
003
80 80 10
11,0
10-11 Natural gas E (H)
002
79 100 10
10,0
10-11 Natural gas LL (L)
002
100 100 10
9,4
10-11 Liqiud gas
(Butan /Propan)
002
88 88 10
11,0
20-11 Natural gas E (H)
002
79 79 100 79 10
10,0
20-11 Natural gas LL (L)
002
100 100 100 100 10
9,4
20-11 Liqiud gas
(Butan /Propan)
002
88 88 88 88 10
11,0
12-21 Natural gas E (H)
001
75 100 10
10,0 With Intake hose 200mm
12-21 Natural gas LL (L)
001
95 100 10
9,2
12-21 Liqiud gas
(Butan /Propan)
001
80 100 10
11,0 With Intake hose 500mm
20-21 Natural gas E (H)
001
75 78 100 100 10
10,0 With Intake hose 200mm
only upper chamber
20-21 Natural gas LL (L)
001
95 100 100 100 10
9,2
20-21 Liqiud gas
(Butan /Propan)
001
80 85 100 100 10
11,0 With Intake hose 500mm
both chambers
Setting Service-Menue Combi-Steamer Genius Gas
ÎProceed to “service“ menu and set the correct gas type prior to adjusting the CO
2
content.
Settings Gas 14:00
Natural Gas 2E/2H
Natural Gas 2LL/2L
Liqiud gas 3B/P
Operating load 79 %
Operating load lower chamber 79 %
Ignition load 100 %
Ignition upper chamber 100 %
Ignition time 10 sec
Menu
back
9