5.1.3. Connection to exhaust gas systems (natural lift or forced ventilation)
Connections to chimneys (with flow safeguard) must be in accordance with the
German Standard DIN 18160, section 1. Connections to an exhaust gas evacuation
system must be according to DVGW regulations, work sheet G 660.
Respectively observe vigorously the local regulations, prescriptions and standards
The gas fitter will make the necessary
assessment of the room size and ventilation.
Prior to connection to an exhaust gas
evacuation system, send for the area master
chimney-sweep.
When connecting to an exhaust gas
evacuation, it is necessary to have the flow
safeguard installed.
Pay attention to the exhaust gas temperatures!
All parts (pipes, fans) which come into contact
with hot exhaust gas must be heat–resistant.
Flow safeguard