Eloma Combi Steamer Multimax A, Multimax B, Genius T Gas units nius T 6-11 Genius T 10-11 Genius T 20-11 Genius T 12-21 Installation and Technical Connections 791342 Inst. Gas 2.
Installation instructions Installation instructions Combi Steamer Multimax B / Genius T Gas 6-11, 10-11, 20-11, 12-21, 20-21 Table of contents Set up ............................................................................................................................................3 Equipment set up .......................................................................................................................3 Table top models 6-11 and 10-11...................................................
Dear customer, These installation instructions contain details about setting, installing and adjusting the combi steamers Genius T 6-11, 10-11, 20-11, 12-21 and 20-21 Gas. Pass on these instructions to the gas fitters and ensure that they are precisely followed when the combi steamer is being installed, otherwise functional faults may occur. After use, keep the installation instructions in a safe place.
1. Set up 1.1 Equipment set up Follow the local regulations and observe the instructions for the installation of kitchen and shop equipment. − In case of installation close to materials that risk burning, observe the instructions of fire prevention. − Avoid to have any other heat and/or steam sources behind or next to the unit. If this is impossible, ensure sufficient clearance or provide for appropriate protection. No heat or humidity must penetrate through the cooling slots into the unit.
− For maintenance and easy access to the unit for service operations use flexible water and electric connections. The appliance should be removable approximately 1 meter from its standard position. 1.4 Hints for setting up − The floor underneath the appliance must be plane to ensure a smooth driving-in of the trolley (roll-in pan-rack). In case of a sloping floor underneath the unit, the trolley will be placed in an oblique position, which might influence its proper functioning.
2. Water supply EWk / TWk Connection to the drinking water supply in accordance with the German standard DIN 1988, section 4 . − In accordance with DVGW instructions (German Gas and Water Standard), the appliance is intrinsically safe and can be connected to the drinking water supply without additional preventive measures.
2.4 Diagram of connection 2.4.1 Water connection for fresh water with water softener 2.4.2 Water connection for Osmosis / Softened water and fresh water 2.4.3 Water connection for Osmosis / Softened water 2.5 Water pressure Min. 200 kPa = 2 bar Max. 600 kPa = 6 bar 2.6 Max. flow rate Typ Softened water l/h Hard water l/h 791342 Inst. Gas 2.
2.7 Heat emission into the area Typ Connected load latent sensible 3. kW kJ/h kJ/h 6-11 12.0 4.320 3.672 10-11 20.0 7.200 6.120 20-11 40.0 14.400 12.240 12-21 35.0 12.600 10.710 20-21 70.0 25.200 21.420 Electrical connection EZ und Potential equalisation PE Do not connect the unit to the mains if it has just been transported from a cold environment into a warm room. Otherwise condensate may develop inside the combi steamer which may cause damages.
4. Water drain A Connect drain to the waste water system in accordance with the German standard DIN 1986, section 1. − For UK the inlet supply shall be fed via fluid backflow prevention category three arrangement such as a double check valve.
5. Installation instructions 5.1 Setting–up possibilities The DVGW (DVGW = German technical scientific association on gas and water) and the Technical regulations for liquid gas installations TRGI 86/96 give systematic information about the different types of gas appliances, their exhaust gas evacuation and their combustion air supply. Consequently, do observe vigorously the local regulations, prescriptions and standards of your country for the installation of catering gas appliances.
5.1.3. Connection to exhaust gas systems (natural lift or forced ventilation) Connections to chimneys (with flow safeguard) must be in accordance with the German Standard DIN 18160, section 1. Connections to an exhaust gas evacuation system must be according to DVGW regulations, work sheet G 660. Respectively observe vigorously the local regulations, prescriptions and standards • The gas fitter will make the necessary assessment of the room size and ventilation.
6 Connect mains cable • Connection, conversion and repair of gas–consuming equipment in catering kitchens and the remedying of faults in equipment of this type, may only be carried out by - the gas supply company, - a skilled representative of the manufacturer (with DVGW or any local certificate), - a contract installation company or - a sales organisation authorised by a liquid gas distribution company. • Before making any connections, inform the responsible gas supply company.
7. Initial start-up The initial start up procedure must also be carried out when setting up unit, after longer operational interruptions or after maintenance work (filling of gas inlet). Î Insert fat filter and drain sieve into the cooking chamber Î Insert left and right hand-in racks into the cooking chamber. Î Follow the instructions for using the water softener Î Open the gas shut–off valve at the installation site.
8.
Setting Service-Menue Combi-Steamer Multimax B Gas Î Before adjusting the CO2 content, the right type of gas must be selected in the service menu. To change the gas type, please set the following parameters: Adjust time “3:45:00 AM”, and press the “Manual steaming” key for at least 2 seconds. The time display briefly shows the software version, then Pr; the temperature display shows End. You can now use the rotary selector switches to enter the different parameters according to the table below.
Adjustment of CO2 content • The lable indicating the type of gas and pre-set gas pressure, is located near the type plate. • When converting the gas type, it is necessary to set the CO²-content according to the overview in 3.2. • The settings must be changed in the Service Menue. • Loosening the regulating screw increases the CO² content. • Tightening the regulating screw decreases the CO² content. • The suction hose should be mounted on the Venturi before the setting, if necessary.
9.
Dimensioned sketch Combi Steamer Genius T Gas 6-11 Housing dimensions and technical connections of models Multimax B, are identical Lga Lrg A EWk TWk EZ PE x R KS EK Ga Flow safeguard Ventilation Drain DN 50 Softened water cold G3/4A Drinking water cold G3/4A Power supplay Potential equalisation Adjustable height range +/- 20 Cleaner Rinse agent Serial interface Gas 1/2“ For left hand hinged units, see their dimensioned sketches ! 791342 Inst. Gas 2.
Dimensioned sketch Combi Steamer Genius T Gas 10-11 Housing dimensions and technical connections of models Multimax B, are identical Lga Lrg A EWk TWk EZ PE x R KS EK Ga Flow safeguard Ventilation Drain DN 50 Softened water cold G3/4A Drinking water cold G3/4A Power supplay Potential equalisation Adjustable height range +/- 20 Cleaner Rinse agent Serial interface Gas 1/2“ For left hand hinged units, see their dimensioned sketches ! 791342 Inst. Gas 2.
Dimensioned sketch Combi Steamer Genius T Gas 20-11 Housing dimensions and technical connections of models Multimax B, are identical Lga Lrg A EWk TWk EZ PE x R KS EK Ga Flow safeguard Ventilation Drain DN 50 Softened water cold G3/4A Drinking water cold G3/4A Power supplay Potential equalisation Adjustable height range +/- 20 Cleaner Rinse agent Serial interface Gas 1/2“ Technical amendments are reserved ! 791342 Inst. Gas 2.
Dimensioned sketch Combi Steamer Genius T Gas 12-21 Housing dimensions and technical connections of models Multimax B, are identical Lga Lrg A EWk TWk EZ PE x R KS EK Ga Flow safeguard Ventilation Drain DN 50 Softened water cold G3/4A Drinking water cold G3/4A Power supplay Potential equalisation Adjustable height range +/- 20 Cleaner Rinse agent Serial interface Gas 1/2“ Technical amendments are reserved ! 791342 Inst. Gas 2.
Dimensioned sketch Combi Steamer Genius T Gas 20-21 Housing dimensions and technical connections of models Multimax B, are identical Lga Lrg A EWk TWk EZ PE x R KS EK Ga Flow safeguard Ventilation Drain DN 50 Softened water cold G3/4A Drinking water cold G3/4A Power supplay Potential equalisation Adjustable height range +/- 20 Cleaner Rinse agent Serial interface Gas 1/2“ Technical amendments are reserved ! 791342 Inst. Gas 2.
- 20 -